fix repeatable migrations
This commit is contained in:
263
db/routines/R__039_fn_planning_site_context.sql
Normal file
263
db/routines/R__039_fn_planning_site_context.sql
Normal file
@@ -0,0 +1,263 @@
|
||||
-- jeden jsonb snapshot pro LP: režim, baterie, síť, EV, TČ, tuv stats
|
||||
|
||||
create or replace function ems.fn_planning_site_context(p_site_id int)
|
||||
returns jsonb
|
||||
language plpgsql
|
||||
stable
|
||||
as $fn$
|
||||
declare
|
||||
v_mode text;
|
||||
v_b jsonb;
|
||||
v_hp jsonb;
|
||||
v_grid jsonb;
|
||||
v_veh jsonb;
|
||||
v_ev jsonb;
|
||||
v_soc_pct numeric;
|
||||
v_soc_wh numeric;
|
||||
v_tuv numeric;
|
||||
v_tuv_stats jsonb;
|
||||
v_uc numeric;
|
||||
v_min_soc_wh numeric;
|
||||
v_arb_wh numeric;
|
||||
v_soc_max_wh numeric;
|
||||
begin
|
||||
if not exists (select 1 from ems.site s where s.id = p_site_id) then
|
||||
return jsonb_build_object('error', 'unknown_site');
|
||||
end if;
|
||||
|
||||
select som.mode_code
|
||||
into v_mode
|
||||
from ems.site_operating_mode som
|
||||
where som.site_id = p_site_id;
|
||||
|
||||
select jsonb_build_object(
|
||||
'usable_capacity_wh', ab.usable_capacity_wh,
|
||||
'min_soc_wh', (ab.min_soc_percent / 100.0 * ab.usable_capacity_wh)::numeric,
|
||||
'arb_floor_wh', (ab.reserve_soc_percent / 100.0 * ab.usable_capacity_wh)::numeric,
|
||||
'reserve_soc_wh', (ab.reserve_soc_percent / 100.0 * ab.usable_capacity_wh)::numeric,
|
||||
'soc_max_wh', (ab.max_soc_percent / 100.0 * ab.usable_capacity_wh)::numeric,
|
||||
'charge_efficiency', ab.charge_efficiency,
|
||||
'discharge_efficiency', ab.discharge_efficiency,
|
||||
'degradation_cost_czk_kwh', ab.degradation_cost_czk_kwh,
|
||||
'max_charge_power_w', least(
|
||||
coalesce(ai.max_battery_charge_w, ai.max_charge_power_w),
|
||||
coalesce(
|
||||
ab.bms_max_charge_w,
|
||||
case when ab.max_charge_c_rate is not null
|
||||
then (ab.max_charge_c_rate * ab.usable_capacity_wh)::bigint
|
||||
end,
|
||||
coalesce(ai.max_battery_charge_w, ai.max_charge_power_w)
|
||||
)
|
||||
)::int,
|
||||
'max_discharge_power_w', least(
|
||||
coalesce(ai.max_battery_discharge_w, ai.max_discharge_power_w),
|
||||
coalesce(
|
||||
ab.bms_max_discharge_w,
|
||||
case when ab.max_discharge_c_rate is not null
|
||||
then (ab.max_discharge_c_rate * ab.usable_capacity_wh)::bigint
|
||||
end,
|
||||
coalesce(ai.max_battery_discharge_w, ai.max_discharge_power_w)
|
||||
)
|
||||
)::int,
|
||||
'charge_slot_buffer', ab.charge_slot_buffer,
|
||||
'discharge_slot_buffer', ab.discharge_slot_buffer
|
||||
)
|
||||
into v_b
|
||||
from ems.asset_battery ab
|
||||
join ems.asset_inverter ai on ai.id = ab.inverter_id and ai.site_id = ab.site_id
|
||||
where ab.site_id = p_site_id
|
||||
order by ab.id
|
||||
limit 1;
|
||||
|
||||
if v_b is null then
|
||||
raise exception 'No asset_battery for site_id=%', p_site_id;
|
||||
end if;
|
||||
|
||||
v_uc := (v_b->>'usable_capacity_wh')::numeric;
|
||||
v_min_soc_wh := (v_b->>'min_soc_wh')::numeric;
|
||||
v_soc_max_wh := (v_b->>'soc_max_wh')::numeric;
|
||||
|
||||
if (v_b->>'max_charge_power_w')::int <= 0 or (v_b->>'max_discharge_power_w')::int <= 0 then
|
||||
raise exception 'Invalid battery effective limits for site_id=%', p_site_id;
|
||||
end if;
|
||||
|
||||
select jsonb_build_object(
|
||||
'rated_heating_power_w', greatest(coalesce(hp.rated_heating_power_w, 8000), 0)::int,
|
||||
'tuv_min_temp_c', coalesce(hp.tuv_min_temp_c, 45)::numeric,
|
||||
'tuv_target_temp_c', coalesce(hp.tuv_target_temp_c, 55)::numeric
|
||||
)
|
||||
into v_hp
|
||||
from ems.asset_heat_pump hp
|
||||
where hp.site_id = p_site_id
|
||||
order by hp.id
|
||||
limit 1;
|
||||
|
||||
if v_hp is null then
|
||||
v_hp := jsonb_build_object(
|
||||
'rated_heating_power_w', 0,
|
||||
'tuv_min_temp_c', 0,
|
||||
'tuv_target_temp_c', 55
|
||||
);
|
||||
end if;
|
||||
|
||||
select jsonb_build_object(
|
||||
'max_import_power_w', sgc.max_import_power_w,
|
||||
'max_export_power_w', sgc.max_export_power_w
|
||||
)
|
||||
into v_grid
|
||||
from ems.site_grid_connection sgc
|
||||
where sgc.site_id = p_site_id
|
||||
order by sgc.id
|
||||
limit 1;
|
||||
|
||||
if v_grid is null then
|
||||
raise exception 'No site_grid_connection for site_id=%', p_site_id;
|
||||
end if;
|
||||
|
||||
select coalesce(
|
||||
jsonb_agg(
|
||||
jsonb_build_object(
|
||||
'max_charge_power_w', v.max_charge_power_w,
|
||||
'battery_capacity_kwh', v.battery_capacity_kwh,
|
||||
'default_target_soc_pct', v.default_target_soc_pct
|
||||
)
|
||||
order by ch.code
|
||||
),
|
||||
'[]'::jsonb
|
||||
)
|
||||
into v_veh
|
||||
from ems.asset_vehicle v
|
||||
join ems.asset_ev_charger ch on ch.id = v.default_charger_id
|
||||
where v.site_id = p_site_id
|
||||
and ch.code in ('ev-charger-1', 'ev-charger-2');
|
||||
|
||||
v_ev := jsonb_build_array(
|
||||
(
|
||||
select case
|
||||
when es.target_deadline is null then null::jsonb
|
||||
when v.battery_capacity_kwh is null then null::jsonb
|
||||
when es.soc_at_connect_pct is null then null::jsonb
|
||||
when coalesce(es.target_soc_pct, v.default_target_soc_pct) is null then null::jsonb
|
||||
when greatest(
|
||||
0,
|
||||
(coalesce(es.target_soc_pct, v.default_target_soc_pct)::numeric
|
||||
- es.soc_at_connect_pct::numeric) / 100.0
|
||||
* (v.battery_capacity_kwh * 1000)
|
||||
- coalesce(es.energy_delivered_wh, 0)::numeric
|
||||
) <= 0 then null::jsonb
|
||||
else jsonb_build_object(
|
||||
'target_deadline', es.target_deadline,
|
||||
'energy_needed_wh', greatest(
|
||||
0,
|
||||
(coalesce(es.target_soc_pct, v.default_target_soc_pct)::numeric
|
||||
- es.soc_at_connect_pct::numeric) / 100.0
|
||||
* (v.battery_capacity_kwh * 1000)
|
||||
- coalesce(es.energy_delivered_wh, 0)::numeric
|
||||
)
|
||||
)
|
||||
end
|
||||
from ems.ev_session es
|
||||
join ems.asset_ev_charger ch on ch.id = es.charger_id
|
||||
left join ems.asset_vehicle v on v.id = es.vehicle_id
|
||||
where es.site_id = p_site_id
|
||||
and es.session_end is null
|
||||
and ch.code = 'ev-charger-1'
|
||||
limit 1
|
||||
),
|
||||
(
|
||||
select case
|
||||
when es.target_deadline is null then null::jsonb
|
||||
when v.battery_capacity_kwh is null then null::jsonb
|
||||
when es.soc_at_connect_pct is null then null::jsonb
|
||||
when coalesce(es.target_soc_pct, v.default_target_soc_pct) is null then null::jsonb
|
||||
when greatest(
|
||||
0,
|
||||
(coalesce(es.target_soc_pct, v.default_target_soc_pct)::numeric
|
||||
- es.soc_at_connect_pct::numeric) / 100.0
|
||||
* (v.battery_capacity_kwh * 1000)
|
||||
- coalesce(es.energy_delivered_wh, 0)::numeric
|
||||
) <= 0 then null::jsonb
|
||||
else jsonb_build_object(
|
||||
'target_deadline', es.target_deadline,
|
||||
'energy_needed_wh', greatest(
|
||||
0,
|
||||
(coalesce(es.target_soc_pct, v.default_target_soc_pct)::numeric
|
||||
- es.soc_at_connect_pct::numeric) / 100.0
|
||||
* (v.battery_capacity_kwh * 1000)
|
||||
- coalesce(es.energy_delivered_wh, 0)::numeric
|
||||
)
|
||||
)
|
||||
end
|
||||
from ems.ev_session es
|
||||
join ems.asset_ev_charger ch on ch.id = es.charger_id
|
||||
left join ems.asset_vehicle v on v.id = es.vehicle_id
|
||||
where es.site_id = p_site_id
|
||||
and es.session_end is null
|
||||
and ch.code = 'ev-charger-2'
|
||||
limit 1
|
||||
)
|
||||
);
|
||||
|
||||
select ti.battery_soc_percent
|
||||
into v_soc_pct
|
||||
from ems.telemetry_inverter ti
|
||||
where ti.site_id = p_site_id
|
||||
order by ti.measured_at desc
|
||||
limit 1;
|
||||
|
||||
if v_soc_pct is null then
|
||||
v_soc_wh := v_uc * 0.5;
|
||||
else
|
||||
v_soc_wh := v_soc_pct::numeric / 100.0 * v_uc;
|
||||
end if;
|
||||
|
||||
v_soc_wh := greatest(v_min_soc_wh, least(v_soc_wh, v_soc_max_wh));
|
||||
|
||||
select thp.tuv_tank_temp_c
|
||||
into v_tuv
|
||||
from ems.telemetry_heat_pump thp
|
||||
where thp.site_id = p_site_id
|
||||
order by thp.measured_at desc
|
||||
limit 1;
|
||||
|
||||
v_tuv := coalesce(v_tuv::numeric, 50::numeric);
|
||||
|
||||
select coalesce(
|
||||
jsonb_agg(
|
||||
jsonb_build_object(
|
||||
'dow', tu.day_of_week,
|
||||
'hour', tu.hour_of_day,
|
||||
'delta', tu.avg_temp_delta_c
|
||||
)
|
||||
),
|
||||
'[]'::jsonb
|
||||
)
|
||||
into v_tuv_stats
|
||||
from ems.tuv_usage_stats tu
|
||||
where tu.site_id = p_site_id;
|
||||
|
||||
return jsonb_build_object(
|
||||
'operating_mode', v_mode,
|
||||
'battery', v_b,
|
||||
'heat_pump', v_hp,
|
||||
'grid', v_grid,
|
||||
'vehicles', v_veh,
|
||||
'ev_sessions', v_ev,
|
||||
'soc_wh', v_soc_wh,
|
||||
'tuv_temp', v_tuv,
|
||||
'tuv_delta_stats', v_tuv_stats,
|
||||
'planning_config', coalesce(
|
||||
(
|
||||
select pc.config
|
||||
from ems.planning_config pc
|
||||
where pc.site_id = p_site_id
|
||||
limit 1
|
||||
),
|
||||
'{}'::jsonb
|
||||
)
|
||||
);
|
||||
end;
|
||||
$fn$;
|
||||
|
||||
comment on function ems.fn_planning_site_context(int) is
|
||||
'Kontext pro planning_engine / LP (bez samotného solveru).';
|
||||
Reference in New Issue
Block a user