diff --git a/backend/services/control/inverter.py b/backend/services/control/inverter.py
index 10ef893..0fdbcee 100644
--- a/backend/services/control/inverter.py
+++ b/backend/services/control/inverter.py
@@ -37,6 +37,7 @@ from services.control.modbus_journal import (
from services.control.models import ControlSetpoints
from services.control.repository import _get_current_soc, _load_inverter_config
from services.control.setpoints import (
+ _deye_reg142_limit_control,
_deye_reg143_export_w,
_deye_system_time_register_rows,
_deye_time_point_rows,
@@ -66,7 +67,10 @@ async def write_inverter_setpoints(
raw_bat = setpoints_now.battery_w
grid_w = int(setpoints_now.grid_setpoint_w or 0)
no_export = inv.no_export
- export_lim = _deye_reg143_export_w(no_export, inv.max_export_power_w)
+ export_lim_hw = _deye_reg143_export_w(no_export, inv.max_export_power_w)
+ export_lim = export_lim_hw
+ if int(setpoints_now.grid_export_limit or 0) > 0:
+ export_lim = min(export_lim_hw, int(setpoints_now.grid_export_limit))
max_batt_w_discharge = int(inv.max_discharge_a * BATT_VOLTAGE_V)
tp_discharge_w = 0 if setpoints_now.lock_battery else max_batt_w_discharge
tou_min_pct = _deye_tou_min_soc_pct(inv)
@@ -88,7 +92,13 @@ async def write_inverter_setpoints(
)
zero_exp_mode = int(inv.deye_zero_export_mode or 1)
- selling_mode = 0 if deye_mode == "SELL" else zero_exp_mode
+ selling_mode = _deye_reg142_limit_control(
+ deye_mode=deye_mode,
+ grid_w=grid_w,
+ export_ban=bool(setpoints_now.export_ban),
+ export_mode=setpoints_now.export_mode,
+ zero_export_mode=zero_exp_mode,
+ )
solar_sell = 0 if (setpoints_now.export_ban and deye_mode != "SELL") else 1
export_limit = export_lim
reg178_val = REG178_SELL if deye_mode == "SELL" else REG178_PASSIVE
diff --git a/backend/services/control/models.py b/backend/services/control/models.py
index 0657cb3..35308a0 100644
--- a/backend/services/control/models.py
+++ b/backend/services/control/models.py
@@ -50,6 +50,8 @@ class ControlSetpoints:
target_soc_pct: int | None = None
#: Explicitní fyzický režim z plánu (PASSIVE/SELL/CHARGE).
deye_physical_mode: str | None = None
+ #: Záměr exportu z LP: NONE / PV_SURPLUS / BATTERY_SELL.
+ export_mode: str | None = None
#: True = zákaz exportu (BLOCK_EXPORT) pro daný slot.
export_ban: bool = False
#: True = odpojit GEN port (MI export cutoff) v tomto slotu dle plánu (reg 178 bits0-1).
diff --git a/backend/services/control/setpoints.py b/backend/services/control/setpoints.py
index d56eea0..b747401 100644
--- a/backend/services/control/setpoints.py
+++ b/backend/services/control/setpoints.py
@@ -96,6 +96,8 @@ def _build_setpoints(
export_mode = str(export_mode_raw).strip().upper() if export_mode_raw is not None else None
if export_mode == "NONE":
export_limit = 0
+ elif export_limit <= 0 and grid_sp < 0:
+ export_limit = abs(grid_sp)
# Záporný výkup sám o sobě neblokuje export, pokud plán export explicitně žádá.
export_ban = sell_f is not None and float(sell_f) < 0 and grid_sp >= 0
gen_cutoff_raw = pi.get("deye_gen_cutoff_enabled")
@@ -127,6 +129,7 @@ def _build_setpoints(
ev2_power_w=ev2_w,
target_soc_pct=target_soc,
deye_physical_mode=pm,
+ export_mode=export_mode,
export_ban=bool(export_ban),
deye_gen_cutoff_enabled=bool(gen_cutoff),
effective_sell_price_czk_kwh=sell_f,
@@ -214,6 +217,30 @@ def _deye_reg143_export_w(no_export: bool, max_export_power_w: int | None) -> in
return max(0, int(max_export_power_w or 0))
+def _deye_reg142_limit_control(
+ *,
+ deye_mode: str,
+ grid_w: int,
+ export_ban: bool,
+ export_mode: str | None,
+ zero_export_mode: int,
+) -> int:
+ """
+ Reg 142: 0 = selling first, 1/2 = zero export (load / CT).
+ Plán s exportem (záporný grid_setpoint, bez export_ban) musí povolit prodej FVE do sítě
+ i v PASSIVE — jinak CT instalace (deye_zero_export_mode=2) drží přebytek v baterii.
+ """
+ if deye_mode == "SELL":
+ return 0
+ em = (export_mode or "").strip().upper()
+ if export_ban or em == "NONE" or grid_w >= 0:
+ return int(zero_export_mode)
+ if em in {"PV_SURPLUS", "BATTERY_SELL"}:
+ return 0
+ # starší řádky bez export_mode: záporný grid_setpoint = export záměr
+ return 0
+
+
def _clamp_deye_tou_soc_pct(pct: int) -> int:
return max(5, min(95, pct))
diff --git a/backend/tests/test_control_exporter_tou.py b/backend/tests/test_control_exporter_tou.py
index 8b8cab3..1203783 100644
--- a/backend/tests/test_control_exporter_tou.py
+++ b/backend/tests/test_control_exporter_tou.py
@@ -15,7 +15,11 @@ from services.control.exporter_monolith import (
get_deye_mode,
)
from services.control.models import OperatingModeInfo
-from services.control.setpoints import _build_setpoints, _deye_zero_export_amps_for_passive
+from services.control.setpoints import (
+ _build_setpoints,
+ _deye_reg142_limit_control,
+ _deye_zero_export_amps_for_passive,
+)
def _inv(*, min_soc: int | None = 12, reserve_soc: int | None = 20) -> InverterConfig:
@@ -111,6 +115,43 @@ class DeyeTouParamsTests(unittest.TestCase):
)
self.assertEqual(get_deye_mode(sp), "PASSIVE")
+ def test_reg142_pv_surplus_on_ct_site_uses_selling_first(self) -> None:
+ """KV1/BA81: PASSIVE + plánovaný export FVE nesmí nechat reg142=2 (zero export CT)."""
+ self.assertEqual(
+ _deye_reg142_limit_control(
+ deye_mode="PASSIVE",
+ grid_w=-3000,
+ export_ban=False,
+ export_mode="PV_SURPLUS",
+ zero_export_mode=2,
+ ),
+ 0,
+ )
+
+ def test_reg142_no_export_when_export_ban(self) -> None:
+ self.assertEqual(
+ _deye_reg142_limit_control(
+ deye_mode="PASSIVE",
+ grid_w=-1000,
+ export_ban=True,
+ export_mode="PV_SURPLUS",
+ zero_export_mode=2,
+ ),
+ 2,
+ )
+
+ def test_reg142_legacy_negative_grid_without_export_mode(self) -> None:
+ self.assertEqual(
+ _deye_reg142_limit_control(
+ deye_mode="PASSIVE",
+ grid_w=-2500,
+ export_ban=False,
+ export_mode=None,
+ zero_export_mode=2,
+ ),
+ 0,
+ )
+
def test_build_setpoints_uses_explicit_export_limit(self) -> None:
mode = OperatingModeInfo(
mode_code="AUTO",
diff --git a/db/migration/V078__planning_interval_export.sql b/db/migration/V078__planning_interval_export.sql
new file mode 100644
index 0000000..4ff6c8c
--- /dev/null
+++ b/db/migration/V078__planning_interval_export.sql
@@ -0,0 +1,10 @@
+-- export_mode / export_limit_w z LP — potřeba pro control exporter (reg 142/143)
+
+alter table ems.planning_interval
+ add column if not exists export_mode text,
+ add column if not exists export_limit_w int;
+
+comment on column ems.planning_interval.export_mode is
+ 'Záměr exportu z solveru: NONE / PV_SURPLUS / BATTERY_SELL.';
+comment on column ems.planning_interval.export_limit_w is
+ 'Tvrdý limit exportu do sítě (W) v slotu; 0 = bez exportu.';
diff --git a/db/routines/R__037_fn_planning_run_commit.sql b/db/routines/R__037_fn_planning_run_commit.sql
index 438c536..14a00a3 100644
--- a/db/routines/R__037_fn_planning_run_commit.sql
+++ b/db/routines/R__037_fn_planning_run_commit.sql
@@ -57,6 +57,8 @@ begin
run_id, interval_start,
battery_setpoint_w, battery_soc_target_pct,
grid_setpoint_w,
+ export_mode,
+ export_limit_w,
deye_physical_mode,
deye_gen_cutoff_enabled,
ev1_setpoint_w, ev2_setpoint_w, ev1_via_bat_w, ev2_via_bat_w,
@@ -73,6 +75,8 @@ begin
(r.value->>'battery_setpoint_w')::int,
(r.value->>'battery_soc_target_pct')::numeric,
(r.value->>'grid_setpoint_w')::int,
+ nullif(trim(r.value->>'export_mode'), ''),
+ nullif(r.value->>'export_limit_w', '')::int,
nullif(trim(r.value->>'deye_physical_mode'), ''),
(r.value->>'deye_gen_cutoff_enabled')::boolean,
nullif(r.value->>'ev1_setpoint_w', '')::int,
@@ -97,6 +101,8 @@ begin
run_id, interval_start,
battery_setpoint_w, battery_soc_target_pct,
grid_setpoint_w,
+ export_mode,
+ export_limit_w,
deye_physical_mode,
deye_gen_cutoff_enabled,
ev1_setpoint_w, ev2_setpoint_w, ev1_via_bat_w, ev2_via_bat_w,
@@ -110,6 +116,8 @@ begin
(r.value->>'battery_setpoint_w')::int,
(r.value->>'battery_soc_target_pct')::numeric,
(r.value->>'grid_setpoint_w')::int,
+ nullif(trim(r.value->>'export_mode'), ''),
+ nullif(r.value->>'export_limit_w', '')::int,
nullif(trim(r.value->>'deye_physical_mode'), ''),
(r.value->>'deye_gen_cutoff_enabled')::boolean,
nullif(r.value->>'ev1_setpoint_w', '')::int,
diff --git a/docs/04-modules/control.md b/docs/04-modules/control.md
index bb282f4..82fe680 100644
--- a/docs/04-modules/control.md
+++ b/docs/04-modules/control.md
@@ -10,6 +10,12 @@
- Odešle potvrzovací setpointy do Loxone přes HTTP (Loxone jako exekutor fallback logiky)
- Loguje každý write pro audit
+### `export_mode` / `export_limit_w` (V078+)
+
+Solver ukládá do `planning_interval` záměr exportu (`NONE` / `PV_SURPLUS` / `BATTERY_SELL`) a cap `export_limit_w`. Control exporter podle toho nastaví **reg 142** a **reg 143** — u CT instalací (`deye_zero_export_mode = 2`) musí být při plánovaném exportu FVE **reg 142 = 0** (selling first), jinak invertor drží přebytek v bateri místo v síti.
+
+Implementace: `setpoints._deye_reg142_limit_control`, `inverter.write_inverter_setpoints`. Ověření: log `reg142=0` při `export_mode=PV_SURPLUS`, audit `flow_pv_to_grid_wh` > 0.
+
---
## Architektura řízení
diff --git a/docs/04-modules/modbus-registers.md b/docs/04-modules/modbus-registers.md
index 6049bf1..c3eada5 100644
--- a/docs/04-modules/modbus-registers.md
+++ b/docs/04-modules/modbus-registers.md
@@ -97,7 +97,7 @@ Solver předvybírá sloty pro nabíjení a export-vybíjení (`_select_charge_s
| **Deye mode** | CHARGE | PASSIVE | SELL | PASSIVE |
| **108** charge A | dle `bat_w` | **0** při exportu bez vybíjení | **0** | max nebo **0** dle varianty |
| **109** discharge A | **0** | max | **max** | **0** při importu bez nabíjení, jinak max |
-| **142** limit control | `deye_zero_export_mode` (1 nebo 2) | `deye_zero_export_mode` (1 nebo 2) | **0** (selling first) | `deye_zero_export_mode` (1 nebo 2) |
+| **142** limit control | `deye_zero_export_mode` (1 nebo 2) | **0** (selling first) pokud plán exportuje (`export_mode` PV_SURPLUS / záporný `grid_setpoint_w`, bez `export_ban`); jinak `deye_zero_export_mode` | **0** (selling first) | `deye_zero_export_mode` (1 nebo 2) |
| **145** solar sell | **1** (enabled) | **1** (enabled) | **1** (enabled) | **1** (enabled) |
| **178** peak shaving | 48 (PASSIVE) | 48 (PASSIVE) | **32** (SELL) | 48 (PASSIVE) |
| **143** export limit | max export W z DB | max export W z DB | max export W z DB | max export W z DB |
diff --git a/frontend/src/pages/Planning.tsx b/frontend/src/pages/Planning.tsx
index 017cdfc..c95e2b6 100644
--- a/frontend/src/pages/Planning.tsx
+++ b/frontend/src/pages/Planning.tsx
@@ -342,7 +342,9 @@ function deyeModeBadge(i: PlanningIntervalDto): { label: string; klass: string;
}
let variant = 'max/max'
- if (grid_w < 0 && battery_w >= 0) {
+ if (exportMode === 'PV_SURPLUS' && grid_w < 0) {
+ variant = 'FVE→síť'
+ } else if (grid_w < 0 && battery_w >= 0) {
variant = exportMode === 'PV_SURPLUS' ? 'FVE→síť' : 'export'
}
else if (grid_w > 0 && battery_w <= 0) variant = 'držet bat. (109=0)'
@@ -394,6 +396,7 @@ type ChartRow = {
pv_a_w: number
battery_soc_target_pct: number | null
battery_setpoint_w: number
+ grid_setpoint_w: number
compare_battery_setpoint_w?: number | null
effective_buy_price: number | null
raw: PlanningIntervalDto
@@ -731,6 +734,7 @@ export default function Planning() {
pv_a_w: pvChartFveW(i, nowMs),
battery_soc_target_pct: i.battery_soc_target_pct,
battery_setpoint_w: i.battery_setpoint_w ?? 0,
+ grid_setpoint_w: i.grid_setpoint_w ?? 0,
compare_battery_setpoint_w: compareMap.get(i.interval_start)?.battery_setpoint_w ?? null,
effective_buy_price: i.effective_buy_price,
raw: i,
@@ -1213,6 +1217,16 @@ export default function Planning() {
/>
))}
+