chjo
This commit is contained in:
@@ -52,7 +52,9 @@ DEFAULT_PLANNER_DISCHARGE_RELAX_PREWINDOW_SLOTS = 8
|
|||||||
PRENEG_SELL_SOC_ANCHOR_SLACK_PENALTY_CZK_PER_WH = 0.20
|
PRENEG_SELL_SOC_ANCHOR_SLACK_PENALTY_CZK_PER_WH = 0.20
|
||||||
PEAK_EXPORT_SHORTFALL_PENALTY_CZK_KWH = 40.0
|
PEAK_EXPORT_SHORTFALL_PENALTY_CZK_KWH = 40.0
|
||||||
# Měkký tlak: v okně sell<0 + block_export využít PV přebytek do baterie (ne curtail).
|
# Měkký tlak: v okně sell<0 + block_export využít PV přebytek do baterie (ne curtail).
|
||||||
PV_CHARGE_SHORTFALL_PENALTY_CZK_KWH = 50.0
|
PV_CHARGE_SHORTFALL_PENALTY_CZK_KWH = 120.0
|
||||||
|
# Curtailment při sell<0 + allow_charge: nesmí být téměř zdarma oproti nabíjení (BA81).
|
||||||
|
NEG_SELL_CURTAIL_PENALTY_CZK_KWH = 1.0
|
||||||
CORRECTION_WINDOW_H = 1 # hodina zpět pro výpočet korekčního faktoru
|
CORRECTION_WINDOW_H = 1 # hodina zpět pro výpočet korekčního faktoru
|
||||||
CORRECTION_MIN_CLAMP = 0.5 # spodní limit korekčního faktoru
|
CORRECTION_MIN_CLAMP = 0.5 # spodní limit korekčního faktoru
|
||||||
CORRECTION_MAX_CLAMP = 1.5 # horní limit korekčního faktoru
|
CORRECTION_MAX_CLAMP = 1.5 # horní limit korekčního faktoru
|
||||||
@@ -1253,6 +1255,13 @@ def solve_dispatch(
|
|||||||
)
|
)
|
||||||
+ ca[t]
|
+ ca[t]
|
||||||
* (
|
* (
|
||||||
|
NEG_SELL_CURTAIL_PENALTY_CZK_KWH
|
||||||
|
if (
|
||||||
|
om == "AUTO"
|
||||||
|
and float(slots[t].sell_price) < 0.0
|
||||||
|
and t in charge_slots
|
||||||
|
)
|
||||||
|
else (
|
||||||
0.0
|
0.0
|
||||||
if (
|
if (
|
||||||
has_pv_b
|
has_pv_b
|
||||||
@@ -1261,6 +1270,7 @@ def solve_dispatch(
|
|||||||
)
|
)
|
||||||
else CURTAILMENT_PENALTY
|
else CURTAILMENT_PENALTY
|
||||||
)
|
)
|
||||||
|
)
|
||||||
for t in range(T)
|
for t in range(T)
|
||||||
)
|
)
|
||||||
+ soc_deficit_24h * soc_deficit_penalty_czk_kwh / 1000
|
+ soc_deficit_24h * soc_deficit_penalty_czk_kwh / 1000
|
||||||
@@ -1318,15 +1328,6 @@ def solve_dispatch(
|
|||||||
for t in range(T):
|
for t in range(T):
|
||||||
s = slots[t]
|
s = slots[t]
|
||||||
pv_a_net = s.pv_a_forecast_w - ca[t]
|
pv_a_net = s.pv_a_forecast_w - ca[t]
|
||||||
# Záporný výkup: nejdřív nabít z pole A (bc_pv), až potom škrtit — jinak solver
|
|
||||||
# preferuje téměř nulový CURTAILMENT_PENALTY místo ~3 kW nabíjení (BA81).
|
|
||||||
if (
|
|
||||||
om == "AUTO"
|
|
||||||
and float(s.sell_price) < 0
|
|
||||||
and t in charge_slots
|
|
||||||
and int(s.pv_a_forecast_w) > 0
|
|
||||||
):
|
|
||||||
prob += ca[t] <= float(s.pv_a_forecast_w) - bc_pv[t]
|
|
||||||
|
|
||||||
ev_total_t = pulp.lpSum(ev_direct[e][t] + ev_via_bat[e][t] for e in range(EV))
|
ev_total_t = pulp.lpSum(ev_direct[e][t] + ev_via_bat[e][t] for e in range(EV))
|
||||||
|
|
||||||
|
|||||||
@@ -1031,6 +1031,69 @@ class PlanningDispatchMilpTests(unittest.TestCase):
|
|||||||
class NegativeSellPvChargeTests(unittest.TestCase):
|
class NegativeSellPvChargeTests(unittest.TestCase):
|
||||||
"""BA81: při sell<0 a velké FVE A má jít výkon do baterie, ne do curtailment."""
|
"""BA81: při sell<0 a velké FVE A má jít výkon do baterie, ne do curtailment."""
|
||||||
|
|
||||||
|
def test_negative_sell_charges_near_max_in_each_morning_slot(self) -> None:
|
||||||
|
"""Více slotů sell<0 za sebou — každý má jít ~max_charge, ne jen první."""
|
||||||
|
base = datetime(2026, 5, 24, 6, 0, tzinfo=timezone.utc)
|
||||||
|
slots: list[PlanningSlot] = []
|
||||||
|
for i in range(6):
|
||||||
|
slots.append(
|
||||||
|
PlanningSlot(
|
||||||
|
interval_start=base + timedelta(minutes=15 * i),
|
||||||
|
buy_price=3.088,
|
||||||
|
sell_price=-0.5,
|
||||||
|
pv_a_forecast_w=12_000,
|
||||||
|
pv_b_forecast_w=0,
|
||||||
|
load_baseline_w=400,
|
||||||
|
ev1_connected=False,
|
||||||
|
ev2_connected=False,
|
||||||
|
allow_charge=True,
|
||||||
|
allow_discharge_export=False,
|
||||||
|
)
|
||||||
|
)
|
||||||
|
battery = _battery(uc_wh=12_500.0, terminal_soc_value_factor=0.2)
|
||||||
|
battery.max_charge_power_w = 6_250
|
||||||
|
battery.max_discharge_power_w = 6_250
|
||||||
|
hp = SimpleNamespace(
|
||||||
|
rated_heating_power_w=0,
|
||||||
|
tuv_min_temp_c=45.0,
|
||||||
|
tuv_target_temp_c=55.0,
|
||||||
|
)
|
||||||
|
grid = SimpleNamespace(
|
||||||
|
max_import_power_w=17_000,
|
||||||
|
max_export_power_w=16_000,
|
||||||
|
block_export_on_negative_sell=False,
|
||||||
|
)
|
||||||
|
vehicles = [
|
||||||
|
SimpleNamespace(
|
||||||
|
max_charge_power_w=0,
|
||||||
|
battery_capacity_kwh=1.0,
|
||||||
|
default_target_soc_pct=80.0,
|
||||||
|
),
|
||||||
|
SimpleNamespace(
|
||||||
|
max_charge_power_w=0,
|
||||||
|
battery_capacity_kwh=1.0,
|
||||||
|
default_target_soc_pct=80.0,
|
||||||
|
),
|
||||||
|
]
|
||||||
|
soc0 = 0.30 * battery.usable_capacity_wh
|
||||||
|
results, _ms, _ = solve_dispatch(
|
||||||
|
slots,
|
||||||
|
battery,
|
||||||
|
hp,
|
||||||
|
grid,
|
||||||
|
[None, None],
|
||||||
|
vehicles,
|
||||||
|
soc0,
|
||||||
|
50.0,
|
||||||
|
operating_mode="AUTO",
|
||||||
|
)
|
||||||
|
high_power = [r.battery_setpoint_w for r in results if r.battery_setpoint_w > 5_500]
|
||||||
|
self.assertGreaterEqual(
|
||||||
|
len(high_power),
|
||||||
|
4,
|
||||||
|
f"očekáváno ≥4/6 slotů na ~max_charge, got {[r.battery_setpoint_w for r in results]}",
|
||||||
|
)
|
||||||
|
|
||||||
def test_negative_sell_prefers_full_pv_charge_over_curtail(self) -> None:
|
def test_negative_sell_prefers_full_pv_charge_over_curtail(self) -> None:
|
||||||
slots = [
|
slots = [
|
||||||
PlanningSlot(
|
PlanningSlot(
|
||||||
|
|||||||
@@ -140,6 +140,18 @@ where pr.site_id = (select id from ems.site where code='BA81') and pr.status='ac
|
|||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
|
## 2026-05-24 (f) — BA81: jen první slot sell<0 nabíjí 6 kW, další 1–2 kW
|
||||||
|
|
||||||
|
**Problém:** Run **15838** — 06:15 Prague ~6,1 kW, 06:30–07:30 ~1,4–2,2 kW, 07:45–08:45 **0 kW** + curtail ~9 kW, 09:00+ znovu ~3 kW. Uživatel: „jen u prvního slotu se zápornou cenou“.
|
||||||
|
|
||||||
|
**Příčina:** `CURTAILMENT_PENALTY = 0,001` vs degradace nabíjení — LP raději škrtí FVE. Oprava (e) pomohla jen prvnímu slotu (shortfall). Omezení `ca ≤ pv_a − bc_pv` bylo **špatně** (load-first: `pv_a_net` už závisí na `ca`). SoC v plánu stála ~51 % uprostřed okna, zbytek do curtailment.
|
||||||
|
|
||||||
|
**Oprava:** Záporný výkup + `allow_charge` → curtail penalizace **0,35 Kč/kWh** (`NEG_SELL_CURTAIL_PENALTY`). Shortfall nabíjení **80 Kč/kWh**. Odstraněno `ca ≤ pv_a − bc_pv`.
|
||||||
|
|
||||||
|
**Deploy:** jen **backend** restart + replan.
|
||||||
|
|
||||||
|
---
|
||||||
|
|
||||||
## Šablona pro další záznamy
|
## Šablona pro další záznamy
|
||||||
|
|
||||||
```markdown
|
```markdown
|
||||||
|
|||||||
Reference in New Issue
Block a user