Initial commit
Made-with: Cursor
This commit is contained in:
817
backend/services/planning_engine.py
Normal file
817
backend/services/planning_engine.py
Normal file
@@ -0,0 +1,817 @@
|
||||
# backend/services/planning_engine.py
|
||||
#
|
||||
# EMS Platform – plánovací engine
|
||||
# Obsahuje: hlavní denní plán + rolling 15min replan
|
||||
#
|
||||
# Spouštění (APScheduler v main.py):
|
||||
# scheduler.add_job(run_daily_plan, 'cron', hour=15, minute=0)
|
||||
# scheduler.add_job(run_rolling_replan, 'cron', minute='*/15')
|
||||
|
||||
import time
|
||||
import logging
|
||||
from dataclasses import dataclass, replace
|
||||
from datetime import datetime, timezone, timedelta
|
||||
from types import SimpleNamespace
|
||||
from typing import Optional
|
||||
|
||||
import pulp
|
||||
from pulp import HiGHS_CMD
|
||||
|
||||
logger = logging.getLogger(__name__)
|
||||
|
||||
|
||||
# ============================================================
|
||||
# Konstanty
|
||||
# ============================================================
|
||||
|
||||
HORIZON_HOURS = 36 # horizont denního plánu
|
||||
INTERVAL_H = 0.25 # 15 minut v hodinách
|
||||
CURTAILMENT_PENALTY = 0.001 # Kč/Wh – malá penalizace za omezení FVE pole A
|
||||
SOLVER_TIME_LIMIT = 10 # sekund
|
||||
CORRECTION_WINDOW_H = 1 # hodina zpět pro výpočet korekčního faktoru
|
||||
CORRECTION_MIN_CLAMP = 0.5 # spodní limit korekčního faktoru
|
||||
CORRECTION_MAX_CLAMP = 1.5 # horní limit korekčního faktoru
|
||||
# Útlum korekce: čím dál od aktuálního času, tím méně korigujeme forecast
|
||||
CORRECTION_DECAY_SLOTS = 16 # po 16 slotech (4h) klesne korekce na 0
|
||||
|
||||
|
||||
# ============================================================
|
||||
# Datové třídy (lze nahradit pydantic modely)
|
||||
# ============================================================
|
||||
|
||||
@dataclass
|
||||
class PlanningSlot:
|
||||
interval_start: datetime
|
||||
buy_price: float # Kč/kWh
|
||||
sell_price: float # Kč/kWh
|
||||
pv_a_forecast_w: int # W – pole A (řiditelné)
|
||||
pv_b_forecast_w: int # W – pole B (zelený bonus, pevné)
|
||||
load_baseline_w: int # W – predikce bazální spotřeby
|
||||
ev1_connected: bool
|
||||
ev2_connected: bool
|
||||
|
||||
|
||||
@dataclass
|
||||
class DispatchResult:
|
||||
interval_start: datetime
|
||||
battery_setpoint_w: int # kladné = nabíjení, záporné = vybíjení
|
||||
battery_soc_target: float # % SoC na konci intervalu
|
||||
grid_setpoint_w: int # kladné = import, záporné = export
|
||||
ev1_setpoint_w: Optional[int]
|
||||
ev2_setpoint_w: Optional[int]
|
||||
ev1_via_bat_w: int
|
||||
ev2_via_bat_w: int
|
||||
heat_pump_enabled: bool
|
||||
heat_pump_setpoint_w: int
|
||||
pv_a_curtailed_w: int
|
||||
expected_cost_czk: float
|
||||
effective_buy_price: float
|
||||
effective_sell_price: float
|
||||
|
||||
|
||||
# ============================================================
|
||||
# Korekce forecastu na základě skutečné výroby
|
||||
# ============================================================
|
||||
|
||||
async def compute_correction_factor(
|
||||
site_id: int,
|
||||
now: datetime,
|
||||
db,
|
||||
window_h: float = CORRECTION_WINDOW_H,
|
||||
) -> tuple[float, dict]:
|
||||
"""
|
||||
Spočítá korekční faktor FVE forecastu z posledních window_h hodin.
|
||||
|
||||
Vrátí (factor, log_data) kde factor je v rozsahu [CORRECTION_MIN_CLAMP, CORRECTION_MAX_CLAMP].
|
||||
factor = 1.0 pokud není dostatek dat nebo je rozdíl zanedbatelný.
|
||||
"""
|
||||
window_start = now - timedelta(hours=window_h)
|
||||
|
||||
# Skutečná výroba za okno (z telemetrie)
|
||||
actual = await db.fetchval("""
|
||||
SELECT COALESCE(SUM(pv_power_w) * 0.25 / 1000.0, 0) -- kWh
|
||||
FROM ems.telemetry_inverter
|
||||
WHERE site_id = $1
|
||||
AND measured_at >= $2 AND measured_at < $3
|
||||
""", site_id, window_start, now)
|
||||
|
||||
# Předpovídaná výroba za stejné okno (z nejnovějšího forecastu který platil tehdy)
|
||||
forecast = await db.fetchval("""
|
||||
SELECT COALESCE(SUM(fpi.power_w) * 0.25 / 1000.0, 0)
|
||||
FROM ems.forecast_pv_interval fpi
|
||||
JOIN ems.forecast_pv_run fpr ON fpr.id = fpi.run_id
|
||||
WHERE fpr.site_id = $1
|
||||
AND fpi.interval_start >= $2 AND fpi.interval_start < $3
|
||||
AND fpr.status = 'ok'
|
||||
AND fpr.created_at = (
|
||||
SELECT MAX(fpr2.created_at)
|
||||
FROM ems.forecast_pv_run fpr2
|
||||
WHERE fpr2.site_id = $1 AND fpr2.status = 'ok'
|
||||
AND fpr2.created_at <= $2
|
||||
)
|
||||
""", site_id, window_start, now)
|
||||
|
||||
log_data = {
|
||||
"window_start": window_start,
|
||||
"window_end": now,
|
||||
"actual_pv_wh": actual * 1000,
|
||||
"forecast_pv_wh": forecast * 1000,
|
||||
}
|
||||
|
||||
# Pokud forecast nebo actual jsou příliš malé (noc, <0.1 kWh) → žádná korekce
|
||||
if forecast < 0.1 or actual < 0.05:
|
||||
log_data["correction_factor"] = 1.0
|
||||
log_data["reason"] = "insufficient_data"
|
||||
return 1.0, log_data
|
||||
|
||||
raw_factor = actual / forecast
|
||||
factor = max(CORRECTION_MIN_CLAMP, min(CORRECTION_MAX_CLAMP, raw_factor))
|
||||
|
||||
log_data["correction_factor"] = factor
|
||||
log_data["raw_factor"] = raw_factor
|
||||
return factor, log_data
|
||||
|
||||
|
||||
def apply_forecast_correction(
|
||||
slots: list[PlanningSlot],
|
||||
now: datetime,
|
||||
factor: float,
|
||||
decay_slots: int = CORRECTION_DECAY_SLOTS,
|
||||
) -> list[PlanningSlot]:
|
||||
"""
|
||||
Aplikuje korekční faktor na FVE forecast zbývajících slotů.
|
||||
Korekce se lineárně utlumuje: na 1. slotu plná korekce,
|
||||
na decay_slots-tém slotu žádná korekce.
|
||||
|
||||
Příklad: factor=0.85, slot 0 → pv_a *= 0.85, slot 8 → pv_a *= 0.925, slot 16+ → žádná korekce
|
||||
"""
|
||||
corrected = []
|
||||
for i, slot in enumerate(slots):
|
||||
if factor == 1.0 or i >= decay_slots:
|
||||
corrected.append(slot)
|
||||
continue
|
||||
|
||||
# Lineární útlum: weight klesá od 1.0 (slot 0) do 0.0 (slot decay_slots)
|
||||
weight = 1.0 - (i / decay_slots)
|
||||
effective_factor = 1.0 + (factor - 1.0) * weight
|
||||
|
||||
corrected.append(
|
||||
replace(
|
||||
slot,
|
||||
pv_a_forecast_w=max(0, int(slot.pv_a_forecast_w * effective_factor)),
|
||||
pv_b_forecast_w=max(0, int(slot.pv_b_forecast_w * effective_factor)),
|
||||
)
|
||||
)
|
||||
|
||||
return corrected
|
||||
|
||||
|
||||
# ============================================================
|
||||
# LP Solver
|
||||
# ============================================================
|
||||
|
||||
def solve_dispatch(
|
||||
slots: list[PlanningSlot],
|
||||
battery,
|
||||
heat_pump,
|
||||
grid,
|
||||
ev_sessions: list, # aktivní EV sessions [ev1_session, ev2_session]
|
||||
vehicles: list, # [vehicle1, vehicle2]
|
||||
current_soc_wh: float,
|
||||
current_tuv_temp_c: float,
|
||||
) -> tuple[list[DispatchResult], int]:
|
||||
"""
|
||||
LP solver pro dispatch optimalizaci.
|
||||
Vrátí (výsledky, solver_duration_ms).
|
||||
"""
|
||||
T = len(slots)
|
||||
EV = len(vehicles) # počet EV (typicky 2)
|
||||
|
||||
EV_ROUNDTRIP_FACTOR = 1.0 / (battery.charge_efficiency * battery.discharge_efficiency)
|
||||
|
||||
prob = pulp.LpProblem("ems_dispatch", pulp.LpMinimize)
|
||||
|
||||
# --- Proměnné ---
|
||||
gi = [pulp.LpVariable(f"gi_{t}", 0, grid.max_import_power_w) for t in range(T)]
|
||||
ge = [pulp.LpVariable(f"ge_{t}", 0, grid.max_export_power_w) for t in range(T)]
|
||||
bc = [pulp.LpVariable(f"bc_{t}", 0, battery.max_charge_power_w) for t in range(T)]
|
||||
bd = [pulp.LpVariable(f"bd_{t}", 0, battery.max_discharge_power_w) for t in range(T)]
|
||||
soc = [pulp.LpVariable(f"soc_{t}", battery.reserve_soc_wh, battery.soc_max_wh) for t in range(T)]
|
||||
ca = [pulp.LpVariable(f"ca_{t}", 0, slots[t].pv_a_forecast_w) for t in range(T)]
|
||||
hp = [pulp.LpVariable(f"hp_{t}", 0, heat_pump.rated_heating_power_w) for t in range(T)]
|
||||
|
||||
# EV proměnné per vozidlo
|
||||
ev_direct = [[pulp.LpVariable(f"evd_{e}_{t}", 0,
|
||||
min(vehicles[e].max_charge_power_w, grid.max_import_power_w))
|
||||
for t in range(T)] for e in range(EV)]
|
||||
ev_via_bat = [[pulp.LpVariable(f"evb_{e}_{t}", 0,
|
||||
vehicles[e].max_charge_power_w)
|
||||
for t in range(T)] for e in range(EV)]
|
||||
|
||||
# --- Účelová funkce ---
|
||||
prob += pulp.lpSum(
|
||||
gi[t] * slots[t].buy_price * INTERVAL_H / 1000
|
||||
- ge[t] * slots[t].sell_price * INTERVAL_H / 1000
|
||||
+ (bc[t] + bd[t]) * battery.degradation_cost_czk_kwh * INTERVAL_H / 1000
|
||||
+ pulp.lpSum(
|
||||
ev_direct[e][t] * slots[t].buy_price * INTERVAL_H / 1000
|
||||
+ ev_via_bat[e][t] * slots[t].buy_price * EV_ROUNDTRIP_FACTOR * INTERVAL_H / 1000
|
||||
for e in range(EV)
|
||||
)
|
||||
+ ca[t] * CURTAILMENT_PENALTY
|
||||
for t in range(T)
|
||||
)
|
||||
|
||||
# --- Omezení ---
|
||||
for t in range(T):
|
||||
s = slots[t]
|
||||
pv_a_net = s.pv_a_forecast_w - ca[t]
|
||||
|
||||
ev_total_t = pulp.lpSum(ev_direct[e][t] + ev_via_bat[e][t] for e in range(EV))
|
||||
|
||||
# Energetická bilance
|
||||
prob += (
|
||||
pv_a_net + s.pv_b_forecast_w + gi[t] + bd[t]
|
||||
== s.load_baseline_w + ev_total_t + hp[t] + bc[t] + ge[t]
|
||||
)
|
||||
|
||||
# SoC kontinuita
|
||||
soc_prev = current_soc_wh if t == 0 else soc[t - 1]
|
||||
prob += soc[t] == (
|
||||
soc_prev
|
||||
+ bc[t] * battery.charge_efficiency * INTERVAL_H
|
||||
- bd[t] / battery.discharge_efficiency * INTERVAL_H
|
||||
)
|
||||
|
||||
# ev_via_bat kryto z discharge
|
||||
prob += pulp.lpSum(ev_via_bat[e][t] for e in range(EV)) <= bd[t]
|
||||
|
||||
# Záporná prodejní cena → zakázat export
|
||||
if s.sell_price < 0:
|
||||
prob += ge[t] == 0
|
||||
|
||||
# Záporná nákupní cena → cap import na reálnou spotřebu
|
||||
if s.buy_price < 0:
|
||||
prob += gi[t] <= (
|
||||
battery.max_charge_power_w
|
||||
+ sum(v.max_charge_power_w for v in vehicles)
|
||||
+ heat_pump.rated_heating_power_w
|
||||
)
|
||||
|
||||
# EV – limity a připojení
|
||||
for e in range(EV):
|
||||
connected = (
|
||||
(e == 0 and s.ev1_connected) or
|
||||
(e == 1 and s.ev2_connected)
|
||||
)
|
||||
if not connected:
|
||||
prob += ev_direct[e][t] == 0
|
||||
prob += ev_via_bat[e][t] == 0
|
||||
else:
|
||||
prob += ev_direct[e][t] + ev_via_bat[e][t] <= vehicles[e].max_charge_power_w
|
||||
|
||||
# Deadline constraints pro EV
|
||||
for e, session in enumerate(ev_sessions):
|
||||
if session and session.target_deadline and session.energy_needed_wh > 0:
|
||||
t_dl = next(
|
||||
(t for t, s in enumerate(slots) if s.interval_start >= session.target_deadline),
|
||||
T - 1
|
||||
)
|
||||
prob += pulp.lpSum(
|
||||
(ev_direct[e][t] + ev_via_bat[e][t]) * INTERVAL_H
|
||||
for t in range(t_dl + 1)
|
||||
if (e == 0 and slots[t].ev1_connected) or (e == 1 and slots[t].ev2_connected)
|
||||
) >= session.energy_needed_wh
|
||||
|
||||
# Nouzový ohřev TUV
|
||||
if current_tuv_temp_c < heat_pump.tuv_min_temp_c:
|
||||
prob += hp[0] >= heat_pump.rated_heating_power_w * 0.8
|
||||
|
||||
# --- Řešení ---
|
||||
t_start = time.monotonic()
|
||||
solver = HiGHS_CMD(msg=False, timeLimit=SOLVER_TIME_LIMIT)
|
||||
status = prob.solve(solver)
|
||||
duration_ms = int((time.monotonic() - t_start) * 1000)
|
||||
|
||||
if pulp.LpStatus[status] != 'Optimal':
|
||||
raise RuntimeError(f"Solver: {pulp.LpStatus[status]}")
|
||||
|
||||
# --- Post-processing ---
|
||||
results = []
|
||||
for t in range(T):
|
||||
hp_raw = pulp.value(hp[t])
|
||||
hp_on = hp_raw > heat_pump.rated_heating_power_w * 0.3
|
||||
batt_w = round(pulp.value(bc[t]) - pulp.value(bd[t]))
|
||||
grid_w = round(pulp.value(gi[t]) - pulp.value(ge[t]))
|
||||
soc_pct = round(pulp.value(soc[t]) / battery.usable_capacity_wh * 100, 1)
|
||||
|
||||
cost = (
|
||||
pulp.value(gi[t]) * slots[t].buy_price * INTERVAL_H / 1000
|
||||
- pulp.value(ge[t]) * slots[t].sell_price * INTERVAL_H / 1000
|
||||
)
|
||||
|
||||
results.append(DispatchResult(
|
||||
interval_start = slots[t].interval_start,
|
||||
battery_setpoint_w = batt_w,
|
||||
battery_soc_target = soc_pct,
|
||||
grid_setpoint_w = grid_w,
|
||||
ev1_setpoint_w = round(pulp.value(ev_direct[0][t]) + pulp.value(ev_via_bat[0][t]))
|
||||
if slots[t].ev1_connected else None,
|
||||
ev2_setpoint_w = round(pulp.value(ev_direct[1][t]) + pulp.value(ev_via_bat[1][t]))
|
||||
if slots[t].ev2_connected else None,
|
||||
ev1_via_bat_w = round(pulp.value(ev_via_bat[0][t])),
|
||||
ev2_via_bat_w = round(pulp.value(ev_via_bat[1][t])),
|
||||
heat_pump_enabled = hp_on,
|
||||
heat_pump_setpoint_w = heat_pump.rated_heating_power_w if hp_on else 0,
|
||||
pv_a_curtailed_w = round(pulp.value(ca[t])),
|
||||
expected_cost_czk = round(cost, 4),
|
||||
effective_buy_price = slots[t].buy_price,
|
||||
effective_sell_price = slots[t].sell_price,
|
||||
))
|
||||
|
||||
return results, duration_ms
|
||||
|
||||
|
||||
# ============================================================
|
||||
# Denní plán (15:00)
|
||||
# ============================================================
|
||||
|
||||
async def run_daily_plan(site_id: int, db, triggered_by: str = "scheduler:daily") -> tuple[int, int]:
|
||||
"""
|
||||
Hlavní denní plánování. Spouštět v 15:00 po importu cen (14:00)
|
||||
a aktualizaci forecastu (14:30).
|
||||
Horizont: od začátku aktuálního 15min slotu do +36h.
|
||||
"""
|
||||
now = datetime.now(timezone.utc)
|
||||
horizon_from = _current_slot_start(now)
|
||||
horizon_to = horizon_from + timedelta(hours=HORIZON_HOURS)
|
||||
|
||||
logger.info(f"[site={site_id}] Daily plan: {horizon_from} → {horizon_to}")
|
||||
|
||||
slots = await _load_slots(site_id, horizon_from, horizon_to, db)
|
||||
if not slots:
|
||||
raise RuntimeError(f"No planning slots for site_id={site_id} (prices/forecast horizon?)")
|
||||
|
||||
battery, hp, grid, vehicles, ev_sessions, soc_wh, tuv_temp = await _load_site_context(
|
||||
site_id, db
|
||||
)
|
||||
|
||||
results, duration_ms = solve_dispatch(
|
||||
slots, battery, hp, grid, ev_sessions, vehicles, soc_wh, tuv_temp
|
||||
)
|
||||
|
||||
run_id = await _save_planning_run(
|
||||
site_id,
|
||||
results,
|
||||
horizon_from,
|
||||
horizon_to,
|
||||
run_type="daily",
|
||||
triggered_by=triggered_by,
|
||||
replan_from=None,
|
||||
soc_wh=soc_wh,
|
||||
duration_ms=duration_ms,
|
||||
correction=1.0,
|
||||
db=db,
|
||||
)
|
||||
logger.info(f"[site={site_id}] Daily plan done in {duration_ms} ms")
|
||||
return run_id, duration_ms
|
||||
|
||||
|
||||
# ============================================================
|
||||
# Rolling replan (každých 15min)
|
||||
# ============================================================
|
||||
|
||||
async def run_rolling_replan(
|
||||
site_id: int,
|
||||
db,
|
||||
*,
|
||||
triggered_by: str = "scheduler:rolling",
|
||||
allow_skip: bool = True,
|
||||
) -> tuple[Optional[int], Optional[int]]:
|
||||
"""
|
||||
Rolling replan každých 15 minut.
|
||||
1. Zjistí aktuální SoC baterie z telemetrie
|
||||
2. Spočítá korekční faktor FVE forecastu z poslední hodiny
|
||||
3. Aplikuje korekci na forecast zbytku dne (s útlumem)
|
||||
4. Spustí solver pro zbývající horizont aktivního plánu
|
||||
5. Uloží jako nový planning_run (aktivní plán se stane superseded)
|
||||
|
||||
Pokud allow_skip=True (scheduler) a horizont je vyčerpaný → vrátí (None, None).
|
||||
Pokud allow_skip=False (API) → spustí denní plán jako náhradu.
|
||||
"""
|
||||
now = datetime.now(timezone.utc)
|
||||
replan_from = _current_slot_start(now)
|
||||
|
||||
active_run = await db.fetchrow("""
|
||||
SELECT id, horizon_end FROM ems.planning_run
|
||||
WHERE site_id = $1 AND status = 'active'
|
||||
ORDER BY created_at DESC LIMIT 1
|
||||
""", site_id)
|
||||
|
||||
if not active_run:
|
||||
logger.warning(f"[site={site_id}] Rolling replan: no active plan, triggering daily plan")
|
||||
return await run_daily_plan(site_id, db, triggered_by=triggered_by)
|
||||
|
||||
horizon_to = active_run["horizon_end"]
|
||||
|
||||
if (horizon_to - replan_from).total_seconds() < 1800:
|
||||
if allow_skip:
|
||||
logger.info(f"[site={site_id}] Rolling replan: horizon almost exhausted, skipping")
|
||||
return None, None
|
||||
logger.info(f"[site={site_id}] Rolling replan: horizon exhausted, running daily plan")
|
||||
return await run_daily_plan(site_id, db, triggered_by=triggered_by)
|
||||
|
||||
logger.info(f"[site={site_id}] Rolling replan from {replan_from} → {horizon_to}")
|
||||
|
||||
battery, hp, grid, vehicles, ev_sessions, soc_wh, tuv_temp = await _load_site_context(
|
||||
site_id, db
|
||||
)
|
||||
|
||||
correction_factor, correction_log = await compute_correction_factor(site_id, now, db)
|
||||
|
||||
slots = await _load_slots(site_id, replan_from, horizon_to, db)
|
||||
if not slots:
|
||||
logger.warning(f"[site={site_id}] Rolling replan: no slots, running daily plan")
|
||||
return await run_daily_plan(site_id, db, triggered_by=triggered_by)
|
||||
|
||||
slots = apply_forecast_correction(slots, now, correction_factor)
|
||||
|
||||
results, duration_ms = solve_dispatch(
|
||||
slots, battery, hp, grid, ev_sessions, vehicles, soc_wh, tuv_temp
|
||||
)
|
||||
|
||||
run_id = await _save_planning_run(
|
||||
site_id,
|
||||
results,
|
||||
replan_from,
|
||||
horizon_to,
|
||||
run_type="rolling",
|
||||
triggered_by=triggered_by,
|
||||
replan_from=replan_from,
|
||||
soc_wh=soc_wh,
|
||||
duration_ms=duration_ms,
|
||||
correction=correction_factor,
|
||||
db=db,
|
||||
)
|
||||
|
||||
await db.execute(
|
||||
"""
|
||||
INSERT INTO ems.forecast_correction_log
|
||||
(site_id, window_start, window_end, actual_pv_wh, forecast_pv_wh,
|
||||
correction_factor, applied_to_run_id)
|
||||
VALUES ($1,$2,$3,$4,$5,$6,$7)
|
||||
""",
|
||||
site_id,
|
||||
correction_log["window_start"],
|
||||
correction_log["window_end"],
|
||||
correction_log.get("actual_pv_wh"),
|
||||
correction_log.get("forecast_pv_wh"),
|
||||
correction_factor,
|
||||
run_id,
|
||||
)
|
||||
|
||||
logger.info(
|
||||
f"[site={site_id}] Rolling replan done in {duration_ms} ms "
|
||||
f"(correction={correction_factor:.3f})"
|
||||
)
|
||||
return run_id, duration_ms
|
||||
|
||||
|
||||
async def run_plan_api(site_id: int, db, plan_type: str, triggered_by: str = "api") -> tuple[int, int]:
|
||||
"""Ruční / UI spuštění plánu. Vždy vrátí (run_id, solver_duration_ms)."""
|
||||
pt = plan_type.lower().strip()
|
||||
if pt == "daily":
|
||||
return await run_daily_plan(site_id, db, triggered_by=triggered_by)
|
||||
if pt == "rolling":
|
||||
rid, ms = await run_rolling_replan(
|
||||
site_id, db, triggered_by=triggered_by, allow_skip=False
|
||||
)
|
||||
if rid is None or ms is None:
|
||||
raise RuntimeError("Rolling replan did not return a run")
|
||||
return rid, ms
|
||||
raise ValueError(f"Unknown plan_type: {plan_type!r} (use daily or rolling)")
|
||||
|
||||
|
||||
# ============================================================
|
||||
# Pomocné funkce
|
||||
# ============================================================
|
||||
|
||||
def _current_slot_start(dt: datetime) -> datetime:
|
||||
"""Zaokrouhlí čas dolů na začátek aktuálního 15min slotu."""
|
||||
minute = (dt.minute // 15) * 15
|
||||
return dt.replace(minute=minute, second=0, microsecond=0)
|
||||
|
||||
|
||||
def _ev_session_ctx(row) -> Optional[SimpleNamespace]:
|
||||
"""Kontext deadline constraintu pro jedno EV (nebo None)."""
|
||||
if row is None or row["target_deadline"] is None:
|
||||
return None
|
||||
cap_kwh = row["veh_cap_kwh"]
|
||||
if cap_kwh is None:
|
||||
return None
|
||||
cap_wh = float(cap_kwh) * 1000.0
|
||||
tgt = row["target_soc_pct"]
|
||||
if tgt is None:
|
||||
tgt = row["default_target_soc_pct"]
|
||||
if tgt is None:
|
||||
return None
|
||||
tgt_f = float(tgt)
|
||||
soc0 = row["soc_at_connect_pct"]
|
||||
if soc0 is None:
|
||||
return None
|
||||
needed_wh = (tgt_f - float(soc0)) / 100.0 * cap_wh
|
||||
delivered = float(row["energy_delivered_wh"] or 0)
|
||||
remaining = max(0.0, needed_wh - delivered)
|
||||
if remaining <= 0:
|
||||
return None
|
||||
return SimpleNamespace(
|
||||
target_deadline=row["target_deadline"],
|
||||
energy_needed_wh=remaining,
|
||||
)
|
||||
|
||||
|
||||
async def _load_site_context(site_id: int, db):
|
||||
"""
|
||||
Načte baterii, TČ, síť, 2× vozidlo, otevřené EV session, SoC a TUV pro solver.
|
||||
"""
|
||||
brow = await db.fetchrow(
|
||||
"""
|
||||
SELECT bat.usable_capacity_wh,
|
||||
bat.reserve_soc_percent,
|
||||
bat.max_soc_percent,
|
||||
bat.charge_efficiency,
|
||||
bat.discharge_efficiency,
|
||||
bat.degradation_cost_czk_kwh,
|
||||
inv.max_charge_power_w,
|
||||
inv.max_discharge_power_w
|
||||
FROM ems.asset_battery bat
|
||||
JOIN ems.asset_inverter inv ON inv.id = bat.inverter_id AND inv.site_id = bat.site_id
|
||||
WHERE bat.site_id = $1
|
||||
ORDER BY bat.id
|
||||
LIMIT 1
|
||||
""",
|
||||
site_id,
|
||||
)
|
||||
if brow is None:
|
||||
raise RuntimeError(f"No asset_battery for site_id={site_id}")
|
||||
|
||||
uc = float(brow["usable_capacity_wh"])
|
||||
reserve_wh = float(brow["reserve_soc_percent"]) / 100.0 * uc
|
||||
soc_max_wh = float(brow["max_soc_percent"]) / 100.0 * uc
|
||||
battery = SimpleNamespace(
|
||||
usable_capacity_wh=uc,
|
||||
reserve_soc_wh=reserve_wh,
|
||||
soc_max_wh=soc_max_wh,
|
||||
charge_efficiency=float(brow["charge_efficiency"]),
|
||||
discharge_efficiency=float(brow["discharge_efficiency"]),
|
||||
degradation_cost_czk_kwh=float(brow["degradation_cost_czk_kwh"]),
|
||||
max_charge_power_w=int(brow["max_charge_power_w"]),
|
||||
max_discharge_power_w=int(brow["max_discharge_power_w"]),
|
||||
)
|
||||
|
||||
hrow = await db.fetchrow(
|
||||
"""
|
||||
SELECT COALESCE(rated_heating_power_w, 8000) AS rated_heating_power_w,
|
||||
COALESCE(tuv_min_temp_c, 45) AS tuv_min_temp_c
|
||||
FROM ems.asset_heat_pump
|
||||
WHERE site_id = $1
|
||||
ORDER BY id
|
||||
LIMIT 1
|
||||
""",
|
||||
site_id,
|
||||
)
|
||||
if hrow is None:
|
||||
heat_pump = SimpleNamespace(rated_heating_power_w=0, tuv_min_temp_c=0.0)
|
||||
else:
|
||||
hp_w = int(hrow["rated_heating_power_w"])
|
||||
heat_pump = SimpleNamespace(
|
||||
rated_heating_power_w=max(hp_w, 0),
|
||||
tuv_min_temp_c=float(hrow["tuv_min_temp_c"]),
|
||||
)
|
||||
|
||||
grow = await db.fetchrow(
|
||||
"""
|
||||
SELECT max_import_power_w, max_export_power_w
|
||||
FROM ems.site_grid_connection
|
||||
WHERE site_id = $1
|
||||
ORDER BY id
|
||||
LIMIT 1
|
||||
""",
|
||||
site_id,
|
||||
)
|
||||
if grow is None:
|
||||
raise RuntimeError(f"No site_grid_connection for site_id={site_id}")
|
||||
grid = SimpleNamespace(
|
||||
max_import_power_w=int(grow["max_import_power_w"]),
|
||||
max_export_power_w=int(grow["max_export_power_w"]),
|
||||
)
|
||||
|
||||
vrows = await db.fetch(
|
||||
"""
|
||||
SELECT v.battery_capacity_kwh,
|
||||
v.max_charge_power_w,
|
||||
v.default_target_soc_pct,
|
||||
ch.code AS charger_code
|
||||
FROM ems.asset_vehicle v
|
||||
JOIN ems.asset_ev_charger ch ON ch.id = v.default_charger_id
|
||||
WHERE v.site_id = $1
|
||||
AND ch.code IN ('ev-charger-1', 'ev-charger-2')
|
||||
ORDER BY ch.code
|
||||
""",
|
||||
site_id,
|
||||
)
|
||||
vehicles: list[SimpleNamespace] = [
|
||||
SimpleNamespace(
|
||||
max_charge_power_w=int(r["max_charge_power_w"]),
|
||||
battery_capacity_kwh=float(r["battery_capacity_kwh"]),
|
||||
default_target_soc_pct=float(r["default_target_soc_pct"]),
|
||||
)
|
||||
for r in vrows
|
||||
]
|
||||
while len(vehicles) < 2:
|
||||
vehicles.append(
|
||||
SimpleNamespace(
|
||||
max_charge_power_w=0,
|
||||
battery_capacity_kwh=1.0,
|
||||
default_target_soc_pct=80.0,
|
||||
)
|
||||
)
|
||||
|
||||
srows = await db.fetch(
|
||||
"""
|
||||
SELECT es.target_deadline,
|
||||
es.target_soc_pct,
|
||||
es.soc_at_connect_pct,
|
||||
es.energy_delivered_wh,
|
||||
ch.code AS charger_code,
|
||||
v.battery_capacity_kwh AS veh_cap_kwh,
|
||||
v.default_target_soc_pct
|
||||
FROM ems.ev_session es
|
||||
JOIN ems.asset_ev_charger ch ON ch.id = es.charger_id
|
||||
LEFT JOIN ems.asset_vehicle v ON v.id = es.vehicle_id
|
||||
WHERE es.site_id = $1
|
||||
AND es.session_end IS NULL
|
||||
""",
|
||||
site_id,
|
||||
)
|
||||
by_charger = {r["charger_code"]: r for r in srows}
|
||||
ev_sessions = [
|
||||
_ev_session_ctx(by_charger.get("ev-charger-1")),
|
||||
_ev_session_ctx(by_charger.get("ev-charger-2")),
|
||||
]
|
||||
|
||||
soc_pct = await db.fetchval(
|
||||
"""
|
||||
SELECT battery_soc_percent
|
||||
FROM ems.telemetry_inverter
|
||||
WHERE site_id = $1
|
||||
ORDER BY measured_at DESC
|
||||
LIMIT 1
|
||||
""",
|
||||
site_id,
|
||||
)
|
||||
if soc_pct is None:
|
||||
soc_wh = reserve_wh
|
||||
else:
|
||||
soc_wh = float(soc_pct) / 100.0 * uc
|
||||
soc_wh = max(reserve_wh, min(soc_wh, soc_max_wh))
|
||||
|
||||
tuv = await db.fetchval(
|
||||
"""
|
||||
SELECT tuv_tank_temp_c
|
||||
FROM ems.telemetry_heat_pump
|
||||
WHERE site_id = $1
|
||||
ORDER BY measured_at DESC
|
||||
LIMIT 1
|
||||
""",
|
||||
site_id,
|
||||
)
|
||||
tuv_temp = float(tuv) if tuv is not None else 50.0
|
||||
|
||||
return battery, heat_pump, grid, vehicles, ev_sessions, soc_wh, tuv_temp
|
||||
|
||||
|
||||
async def _load_slots(site_id, from_dt, to_dt, db) -> list[PlanningSlot]:
|
||||
"""Načte 15min sloty s cenami, forecasty a stavem EV z DB."""
|
||||
rows = await db.fetch("""
|
||||
SELECT
|
||||
ep.interval_start,
|
||||
ep.effective_buy_price_czk_kwh AS buy_price,
|
||||
ep.effective_sell_price_czk_kwh AS sell_price,
|
||||
COALESCE(fpi_a.power_w, 0) AS pv_a_forecast_w,
|
||||
COALESCE(fpi_b.power_w, 0) AS pv_b_forecast_w,
|
||||
COALESCE(cbi.power_w, 500) AS load_baseline_w,
|
||||
-- EV připojení z aktuálního stavu nabíječek
|
||||
(ev1.status NOT IN ('available', 'unavailable')) AS ev1_connected,
|
||||
(ev2.status NOT IN ('available', 'unavailable')) AS ev2_connected
|
||||
FROM ems.vw_site_effective_price ep
|
||||
-- FVE pole A forecast
|
||||
LEFT JOIN LATERAL (
|
||||
SELECT fpi.power_w FROM ems.forecast_pv_interval fpi
|
||||
JOIN ems.forecast_pv_run fpr ON fpr.id = fpi.run_id
|
||||
JOIN ems.asset_pv_array apa ON apa.id = fpi.pv_array_id AND apa.site_id = fpr.site_id
|
||||
WHERE fpr.site_id = $1 AND apa.code = 'pv-a'
|
||||
AND fpi.interval_start = ep.interval_start AND fpr.status = 'ok'
|
||||
ORDER BY fpr.created_at DESC LIMIT 1
|
||||
) fpi_a ON true
|
||||
-- FVE pole B forecast
|
||||
LEFT JOIN LATERAL (
|
||||
SELECT fpi.power_w FROM ems.forecast_pv_interval fpi
|
||||
JOIN ems.forecast_pv_run fpr ON fpr.id = fpi.run_id
|
||||
JOIN ems.asset_pv_array apa ON apa.id = fpi.pv_array_id AND apa.site_id = fpr.site_id
|
||||
WHERE fpr.site_id = $1 AND apa.code = 'pv-b'
|
||||
AND fpi.interval_start = ep.interval_start AND fpr.status = 'ok'
|
||||
ORDER BY fpr.created_at DESC LIMIT 1
|
||||
) fpi_b ON true
|
||||
-- Bazální spotřeba
|
||||
LEFT JOIN ems.consumption_baseline_interval cbi
|
||||
ON cbi.site_id = $1 AND cbi.interval_start = ep.interval_start
|
||||
AND cbi.data_type = 'forecast'
|
||||
-- Stav EV nabíječek (aktuální, pro celý horizont stejný)
|
||||
LEFT JOIN LATERAL (
|
||||
SELECT t.status
|
||||
FROM ems.telemetry_ev_charger t
|
||||
JOIN ems.asset_ev_charger ch ON ch.id = t.charger_id
|
||||
WHERE t.site_id = $1 AND ch.code = 'ev-charger-1'
|
||||
ORDER BY t.measured_at DESC LIMIT 1
|
||||
) ev1 ON true
|
||||
LEFT JOIN LATERAL (
|
||||
SELECT t.status
|
||||
FROM ems.telemetry_ev_charger t
|
||||
JOIN ems.asset_ev_charger ch ON ch.id = t.charger_id
|
||||
WHERE t.site_id = $1 AND ch.code = 'ev-charger-2'
|
||||
ORDER BY t.measured_at DESC LIMIT 1
|
||||
) ev2 ON true
|
||||
WHERE ep.site_id = $1
|
||||
AND ep.interval_start >= $2 AND ep.interval_start < $3
|
||||
ORDER BY ep.interval_start
|
||||
""", site_id, from_dt, to_dt)
|
||||
|
||||
out: list[PlanningSlot] = []
|
||||
for r in rows:
|
||||
d = dict(r)
|
||||
out.append(
|
||||
PlanningSlot(
|
||||
interval_start=d["interval_start"],
|
||||
buy_price=float(d["buy_price"]),
|
||||
sell_price=float(d["sell_price"]),
|
||||
pv_a_forecast_w=int(d["pv_a_forecast_w"] or 0),
|
||||
pv_b_forecast_w=int(d["pv_b_forecast_w"] or 0),
|
||||
load_baseline_w=int(d["load_baseline_w"] or 0),
|
||||
ev1_connected=bool(d["ev1_connected"]),
|
||||
ev2_connected=bool(d["ev2_connected"]),
|
||||
)
|
||||
)
|
||||
return out
|
||||
|
||||
|
||||
async def _save_planning_run(
|
||||
site_id, results, horizon_from, horizon_to,
|
||||
run_type, triggered_by, replan_from,
|
||||
soc_wh, duration_ms, correction, db
|
||||
) -> int:
|
||||
"""Uloží výsledky solveru jako nový planning_run, deaktivuje předchozí."""
|
||||
run_id = await db.fetchval("""
|
||||
INSERT INTO ems.planning_run
|
||||
(site_id, horizon_start, horizon_end, status,
|
||||
run_type, triggered_by, replan_from,
|
||||
soc_at_replan_wh, solver_duration_ms, forecast_correction_factor)
|
||||
VALUES ($1,$2,$3,'draft',$4,$5,$6,$7,$8,$9)
|
||||
RETURNING id
|
||||
""", site_id, horizon_from, horizon_to,
|
||||
run_type, triggered_by, replan_from,
|
||||
soc_wh, duration_ms, correction)
|
||||
|
||||
# Bulk insert výsledků
|
||||
await db.executemany("""
|
||||
INSERT INTO ems.planning_interval
|
||||
(run_id, interval_start,
|
||||
battery_setpoint_w, battery_soc_target_pct,
|
||||
grid_setpoint_w,
|
||||
ev1_setpoint_w, ev2_setpoint_w, ev1_via_bat_w, ev2_via_bat_w,
|
||||
heat_pump_enabled, heat_pump_setpoint_w,
|
||||
pv_a_curtailed_w, expected_cost_czk,
|
||||
effective_buy_price, effective_sell_price)
|
||||
VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15)
|
||||
""", [
|
||||
(run_id, r.interval_start,
|
||||
r.battery_setpoint_w, r.battery_soc_target,
|
||||
r.grid_setpoint_w,
|
||||
r.ev1_setpoint_w, r.ev2_setpoint_w, r.ev1_via_bat_w, r.ev2_via_bat_w,
|
||||
r.heat_pump_enabled, r.heat_pump_setpoint_w,
|
||||
r.pv_a_curtailed_w, r.expected_cost_czk,
|
||||
r.effective_buy_price, r.effective_sell_price)
|
||||
for r in results
|
||||
])
|
||||
|
||||
# Aktivovat nový plán, supersede předchozí
|
||||
await db.execute("""
|
||||
UPDATE ems.planning_run SET status = 'superseded'
|
||||
WHERE site_id = $1 AND status = 'active' AND id <> $2
|
||||
""", site_id, run_id)
|
||||
|
||||
await db.execute(
|
||||
"UPDATE ems.planning_run SET status = 'active' WHERE id = $1", run_id
|
||||
)
|
||||
|
||||
return run_id
|
||||
Reference in New Issue
Block a user