ladime
This commit is contained in:
@@ -59,7 +59,7 @@ NEG_SELL_CURTAIL_PENALTY_CZK_KWH = 1.0
|
|||||||
NEG_SELL_PV_CHARGE_REWARD_CZK_KWH = 0.8
|
NEG_SELL_PV_CHARGE_REWARD_CZK_KWH = 0.8
|
||||||
# Měkký tlak: v okně sell<0 dobít na soc_max (ne zastavit na ~94 % kvůli curtail).
|
# Měkký tlak: v okně sell<0 dobít na soc_max (ne zastavit na ~94 % kvůli curtail).
|
||||||
NEG_SELL_SOC_UNDERFILL_PENALTY_CZK_PER_WH = 0.35
|
NEG_SELL_SOC_UNDERFILL_PENALTY_CZK_PER_WH = 0.35
|
||||||
PLANNER_BUILD_TAG = "2026-05-24-ba81-soc-headroom-v7"
|
PLANNER_BUILD_TAG = "2026-05-25-neg-sell-no-export-fixed-v8"
|
||||||
CORRECTION_WINDOW_H = 1 # hodina zpět pro výpočet korekčního faktoru
|
CORRECTION_WINDOW_H = 1 # hodina zpět pro výpočet korekčního faktoru
|
||||||
CORRECTION_MIN_CLAMP = 0.5 # spodní limit korekčního faktoru
|
CORRECTION_MIN_CLAMP = 0.5 # spodní limit korekčního faktoru
|
||||||
CORRECTION_MAX_CLAMP = 1.5 # horní limit korekčního faktoru
|
CORRECTION_MAX_CLAMP = 1.5 # horní limit korekčního faktoru
|
||||||
@@ -1641,6 +1641,11 @@ def solve_dispatch(
|
|||||||
prob += ge[t] == 0
|
prob += ge[t] == 0
|
||||||
prob += ge_pv[t] == 0
|
prob += ge_pv[t] == 0
|
||||||
prob += ge_bat[t] == 0
|
prob += ge_bat[t] == 0
|
||||||
|
elif fixed_tariff_like_pre:
|
||||||
|
# BA81: při sell<0 neexportovat (záporná cena výkupu = platíš za export).
|
||||||
|
# Přebytek FVE → baterie / curtail A; B přes z_gen_cutoff nebo bc_pv.
|
||||||
|
prob += ge[t] == 0
|
||||||
|
prob += ge_pv[t] == 0
|
||||||
|
|
||||||
soc_prev_expr = current_soc_wh if t == 0 else soc[t - 1]
|
soc_prev_expr = current_soc_wh if t == 0 else soc[t - 1]
|
||||||
arb_t = arb_floor_series[t]
|
arb_t = arb_floor_series[t]
|
||||||
@@ -1829,13 +1834,18 @@ def solve_dispatch(
|
|||||||
and not getattr(grid, "block_export_on_negative_sell", False)
|
and not getattr(grid, "block_export_on_negative_sell", False)
|
||||||
and sell_t < 0
|
and sell_t < 0
|
||||||
and not fixed_tariff_like_pre
|
and not fixed_tariff_like_pre
|
||||||
|
) or (
|
||||||
|
# KV1: plná baterie + kladný sell — neblokovat ge_pv==0 (jinak masivní curtail).
|
||||||
|
getattr(grid, "block_export_on_negative_sell", False)
|
||||||
|
and sell_t >= 0
|
||||||
|
and pv_surplus_w > 500
|
||||||
)
|
)
|
||||||
# BA81 (fixní tarif + pole B): ge_pv==0 z pv_store by znemožnilo odvést nelimitovatelný
|
# BA81: export pole B jen při kladném sell (po sell<0 jinak ge==0 výše).
|
||||||
# výkon B (plná baterie po sell<0). Místo toho jen strop na pv_b.
|
|
||||||
fixed_pv_b_export_cap = (
|
fixed_pv_b_export_cap = (
|
||||||
fixed_tariff_like_pre
|
fixed_tariff_like_pre
|
||||||
and float(s.pv_b_forecast_w) > 0
|
and float(s.pv_b_forecast_w) > 0
|
||||||
and not getattr(grid, "block_export_on_negative_sell", False)
|
and not getattr(grid, "block_export_on_negative_sell", False)
|
||||||
|
and sell_t >= 0
|
||||||
)
|
)
|
||||||
if fixed_pv_b_export_cap:
|
if fixed_pv_b_export_cap:
|
||||||
if z_gen_cutoff is not None:
|
if z_gen_cutoff is not None:
|
||||||
|
|||||||
@@ -1222,7 +1222,7 @@ class NegativeSellPvChargeTests(unittest.TestCase):
|
|||||||
50.0,
|
50.0,
|
||||||
operating_mode="AUTO",
|
operating_mode="AUTO",
|
||||||
)
|
)
|
||||||
self.assertEqual(snap.get("planner_build_tag"), "2026-05-24-ba81-soc-headroom-v7")
|
self.assertEqual(snap.get("planner_build_tag"), "2026-05-25-neg-sell-no-export-fixed-v8")
|
||||||
self.assertGreater(
|
self.assertGreater(
|
||||||
results[0].battery_setpoint_w,
|
results[0].battery_setpoint_w,
|
||||||
5_500,
|
5_500,
|
||||||
@@ -1366,7 +1366,7 @@ class NegativeSellPvChargeTests(unittest.TestCase):
|
|||||||
50.0,
|
50.0,
|
||||||
operating_mode="AUTO",
|
operating_mode="AUTO",
|
||||||
)
|
)
|
||||||
self.assertEqual(snap.get("planner_build_tag"), "2026-05-24-ba81-soc-headroom-v7")
|
self.assertEqual(snap.get("planner_build_tag"), "2026-05-25-neg-sell-no-export-fixed-v8")
|
||||||
self.assertEqual(len(results), len(slots))
|
self.assertEqual(len(results), len(slots))
|
||||||
|
|
||||||
def test_gen_cutoff_full_soc_neg_sell_with_pv_b_feasible(self) -> None:
|
def test_gen_cutoff_full_soc_neg_sell_with_pv_b_feasible(self) -> None:
|
||||||
@@ -1430,9 +1430,69 @@ class NegativeSellPvChargeTests(unittest.TestCase):
|
|||||||
55.0,
|
55.0,
|
||||||
operating_mode="AUTO",
|
operating_mode="AUTO",
|
||||||
)
|
)
|
||||||
self.assertEqual(snap.get("planner_build_tag"), "2026-05-24-ba81-soc-headroom-v7")
|
self.assertEqual(snap.get("planner_build_tag"), "2026-05-25-neg-sell-no-export-fixed-v8")
|
||||||
self.assertEqual(len(results), len(slots))
|
self.assertEqual(len(results), len(slots))
|
||||||
|
|
||||||
|
def test_fixed_tariff_neg_sell_no_grid_export(self) -> None:
|
||||||
|
"""BA81: sell<0 nesmí vést do sítě (záporná výkupní cena) — jen nabíjení/curtail."""
|
||||||
|
slots = [
|
||||||
|
PlanningSlot(
|
||||||
|
interval_start=datetime(2026, 5, 25, 7, 0, tzinfo=timezone.utc)
|
||||||
|
+ timedelta(minutes=15 * i),
|
||||||
|
buy_price=3.088,
|
||||||
|
sell_price=-0.5,
|
||||||
|
pv_a_forecast_w=10_000,
|
||||||
|
pv_b_forecast_w=2_500,
|
||||||
|
load_baseline_w=300,
|
||||||
|
ev1_connected=False,
|
||||||
|
ev2_connected=False,
|
||||||
|
allow_charge=True,
|
||||||
|
allow_discharge_export=False,
|
||||||
|
charge_acquisition_buy_czk_kwh=3.61,
|
||||||
|
)
|
||||||
|
for i in range(4)
|
||||||
|
]
|
||||||
|
battery = _battery(uc_wh=12_500.0, terminal_soc_value_factor=0.0)
|
||||||
|
battery.soc_max_wh = 12_500.0
|
||||||
|
battery.max_charge_power_w = 6_250
|
||||||
|
grid = SimpleNamespace(
|
||||||
|
max_import_power_w=17_000,
|
||||||
|
max_export_power_w=16_000,
|
||||||
|
block_export_on_negative_sell=False,
|
||||||
|
deye_gen_microinverter_cutoff_enabled=True,
|
||||||
|
)
|
||||||
|
hp = SimpleNamespace(
|
||||||
|
rated_heating_power_w=0,
|
||||||
|
tuv_min_temp_c=45.0,
|
||||||
|
tuv_target_temp_c=55.0,
|
||||||
|
)
|
||||||
|
vehicles = [
|
||||||
|
SimpleNamespace(
|
||||||
|
max_charge_power_w=0,
|
||||||
|
battery_capacity_kwh=1.0,
|
||||||
|
default_target_soc_pct=80.0,
|
||||||
|
),
|
||||||
|
SimpleNamespace(
|
||||||
|
max_charge_power_w=0,
|
||||||
|
battery_capacity_kwh=1.0,
|
||||||
|
default_target_soc_pct=80.0,
|
||||||
|
),
|
||||||
|
]
|
||||||
|
results, _ms, _ = solve_dispatch(
|
||||||
|
slots,
|
||||||
|
battery,
|
||||||
|
hp,
|
||||||
|
grid,
|
||||||
|
[None, None],
|
||||||
|
vehicles,
|
||||||
|
8_000.0,
|
||||||
|
50.0,
|
||||||
|
operating_mode="AUTO",
|
||||||
|
)
|
||||||
|
for r in results:
|
||||||
|
self.assertGreaterEqual(r.battery_setpoint_w, 0, "neg sell má nabíjet")
|
||||||
|
self.assertGreaterEqual(r.grid_setpoint_w, 0, "neg sell bez exportu do sítě")
|
||||||
|
|
||||||
|
|
||||||
class AutoPvSurplusExportTests(unittest.TestCase):
|
class AutoPvSurplusExportTests(unittest.TestCase):
|
||||||
"""Plná baterie + vysoká FVE: export přebytku (ge_pv), ne curtailment, bez SELL."""
|
"""Plná baterie + vysoká FVE: export přebytku (ge_pv), ne curtailment, bez SELL."""
|
||||||
|
|||||||
@@ -5,6 +5,21 @@ Formát: **datum (ISO)** · stručný důvod · soubory · chování / ověřen
|
|||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
|
## 2026-05-25 (l) — Plán 25. 5.: BA81 neg. výkup bez exportu, KV1 ranní curtail
|
||||||
|
|
||||||
|
**Problém (MCP plán run 16346–16350, tag v7):** KV1 06–08 h masivní **curtail** FVE (plná baterie, `ge_pv=0` z pv_store). BA81 při `sell<0` **export ~10 kW** místo nabíjení. Večer slabý export u KV1/home-01 (spot: `sell < buy`).
|
||||||
|
|
||||||
|
**Oprava (tag `2026-05-25-neg-sell-no-export-fixed-v8`):**
|
||||||
|
|
||||||
|
- Fixní tarif (BA81): při **`sell < 0`** tvrdě **`ge = 0`** (jako KV1 s block_export) — přebytek jen baterie/curtail.
|
||||||
|
- **`fixed_pv_b_export_cap`** jen při **`sell ≥ 0`** (po neg. okně export B).
|
||||||
|
- KV1: **`skip_pv_store_block`** při kladném `sell` + PV přebytek — méně curtailu před neg. oknem.
|
||||||
|
|
||||||
|
**Deploy:** služba v compose je **`backend`**, ne `ems-api`. Ověření:
|
||||||
|
`docker compose -f /opt/ems-deploy/docker-compose.yml exec backend grep PLANNER_BUILD_TAG /app/services/planning_engine.py`
|
||||||
|
|
||||||
|
---
|
||||||
|
|
||||||
## 2026-05-24 (k) — BA81: Infeasible při SoC = 100 % (telemetrie = soc_max)
|
## 2026-05-24 (k) — BA81: Infeasible při SoC = 100 % (telemetrie = soc_max)
|
||||||
|
|
||||||
**Problém:** Po v6 stále `Solver: Infeasible` při replanu, když `fn_planning_site_context` vrátí `soc_wh = soc_max_wh` (12 500).
|
**Problém:** Po v6 stále `Solver: Infeasible` při replanu, když `fn_planning_site_context` vrátí `soc_wh = soc_max_wh` (12 500).
|
||||||
|
|||||||
Reference in New Issue