prechazeni omezeni PV A u home-01
Some checks failed
CI and deploy / migration-check (push) Failing after 14s
CI and deploy / deploy (push) Has been skipped

This commit is contained in:
Dusan Vojacek
2026-05-25 23:28:47 +02:00
parent 18ace46ea9
commit b03f08d3a0
5 changed files with 58 additions and 14 deletions

View File

@@ -17,7 +17,7 @@
- **LP (AUTO):** objective explicitně `ge_pv×sell ge_bat×sell + ge_bat×acquisition` v exportních slotech; **bez** cross-slot vynucení `ge_pv ≥ surplus`. Guard FVE: `ge_pv=0` jen pokud `sell < charge_acquisition degrad` (ne `sell < buy` ve slotu). Viz [`planning-arbitrage-accounting.md`](planning-arbitrage-accounting.md).
- **Load-first (Deye, AUTO):** proměnné `pv_ld` (PV → load+EV+TČ), `pv_sp` (přebytek), `bc_pv` / `bc_gi`. Plná bilance `pv_a + pv_b + gi + bd = load + ev + hp + bc + ge`; `bc_pv + ge_pv ≤ pv_sp`; `gi ≤ load + bc_gi`; mimo `allow_discharge_export`: `bd ≤ load pv_ld` a **`pv_ld ≥ load gi bd`**. Snapshot: `load_first_enabled=true`. Test `LoadFirstDispatchTests`.
- **Tvrdé výkonové limity site/baterie:** `gi ≤ site_grid_connection.max_import_power_w` (breaker); **`bc_pv + bc_gi ≤ asset_battery.max_charge_power_w`**; **`ge ≤ max_export_power_w`** (proměnná `ge`, platí `ge = ge_pv + ge_bat`); **`bd + ge_bat ≤ asset_battery.max_discharge_power_w`** (vybíjení do domu + export z baterie nesmí současně překročit BMS). Dříve LP dovoloval import+nabíjení a dvojnásobné nabíjení; u prodeje hrozilo současné `bd` a `ge_bat` až 2× max discharge — viz `SitePowerCapTests`.
- **Hodnota FVE (PV store value):** `ge_pv = 0`, pokud `sell < future_sell_opportunity degradation` (ne `charge_acquisition` — u fixního KV1 by jinak blokoval export při sell 2 Kč). **Před prvním `sell < 0` v horizontu:** při `sell ≥ 0` smí `ge_pv` až do `pv_sp` (strategie BA81: vyvézt přes poledne, pak nabít z FVE v záporném okně). Výjimka **nucený vent** jen plná baterie. Testy `Home01PvStoreValueTests`, `PreNegativeSellExportTests`.
- **Hodnota FVE (PV store value):** tvrdé `ge_pv = 0` jen pokud `sell < future_sell_opportunity degradation` **a** `sell < 0` (spot), nebo u fixního tarifu dle `fixed_pv_b_export_cap`. Při **`sell ≥ 0` (spot home-01, KV1):** `ge_pv` **neblokuje** pv_store — solver volí export vs. `bc_pv` podle `ge_pv×sell` a degradace; **baterii** na večerní peak drží `ge_bat` (`evening_early` / push), ne curtail FVE. **Před prvním `sell < 0`:** `allow_pre_neg_pv_export`. Výjimka **nucený vent** jen plná baterie. Tag `2026-05-28-pv-positive-sell-solver-v29`. Testy `Home01PvStoreValueTests`, `PreNegativeSellExportTests`.
- **Drahý nákup → vlastní spotřeba z baterie:** mimo `allow_charge` platí `bd + pv_ld ≥ load_baseline + hp[t]` a `gi ≤ EV + hp[t]` (ne `hp_rated`). **Spot:** drahý slot = `buy > min(buy≥0) + degradace`. **Fixní nákup (DB `purchase_pricing_mode=fixed` nebo heuristika rozptylu buy &lt; 0,25):** navíc `buy > charge_acquisition + degradace`. Na spotu **nesmí** `charge_acquisition` (~0,9 Kč) označit všechny sloty jako drahé → Infeasible (home-01). Při **Infeasible** solver jednou opakuje s `relaxed_expensive_import` (síť smí krmit baseload v drahých slotech; v `solver_params.inputs.relaxed_expensive_import=true`). Testy `AutoPassiveSelfConsumptionTests`, `test_spot_low_acquisition_does_not_mark_all_slots_expensive`, `test_negative_buy_in_horizon_does_not_block_all_grid_import`.
- **Záporný výkup (`sell < 0`) bez exportu:** `block_export_on_negative_sell` (KV1) **nebo** `purchase_pricing_mode=fixed` (BA81). **Spot (home-01):** `ge_pv=0` dokud není plná baterie; při plné jen ventil pole B (`ge_pv ≤ pv_b`, `w_pv_b_vent_neg`); výboj baterie při `sell<0` jen **12 slotů** před `buy ≤ planner_extreme_buy_threshold` (default 2), pokud spread do budoucna dává smysl — tag `2026-05-26-neg-sell-bat-dump-extreme-buy-v11`. Večerní discharge maska u spotu: denní peak ≥17:00 (ne `sell > ref_buy` v slotu).
- **Pole B při sell&lt;0 (home-01):** pokud `block_export_on_negative_sell = false`, LP nesmí vynutit `ge_pv = 0` (přebytek neriťitelného PV B). KV1 s `block_export = true` jen curtail A / nabíjení.