tuning palnneru
This commit is contained in:
25
db/migration/V077__planner_safety_charge_asset_battery.sql
Normal file
25
db/migration/V077__planner_safety_charge_asset_battery.sql
Normal file
@@ -0,0 +1,25 @@
|
||||
-- Parametry pro denní „safety charge“ (měkké LP penalizace) a kotvu rolling replanu.
|
||||
|
||||
alter table ems.asset_battery
|
||||
add column if not exists planner_daytime_charge_target_enabled boolean not null default true;
|
||||
|
||||
alter table ems.asset_battery
|
||||
add column if not exists planner_night_baseload_buffer_percent numeric not null default 20;
|
||||
|
||||
alter table ems.asset_battery
|
||||
add column if not exists planner_daytime_charge_price_quantile numeric not null default 0.70;
|
||||
|
||||
alter table ems.asset_battery
|
||||
add column if not exists planner_charge_commitment_penalty_czk_kwh numeric not null default 0.20;
|
||||
|
||||
comment on column ems.asset_battery.planner_daytime_charge_target_enabled is
|
||||
'Zapíná SQL/LP měkké denní cíle SoC (safety) z fn_load_planning_slots_full; ne tvrdé allow_charge masky.';
|
||||
|
||||
comment on column ems.asset_battery.planner_night_baseload_buffer_percent is
|
||||
'Procentní přirážka k odhadu nočního baseload Wh (20 = +20 % k night_baseload_target_wh).';
|
||||
|
||||
comment on column ems.asset_battery.planner_daytime_charge_price_quantile is
|
||||
'Rezervováno pro budoucí výběr „drahých“ oken z cenové distribuce; v1 se v LP nepoužívá.';
|
||||
|
||||
comment on column ems.asset_battery.planner_charge_commitment_penalty_czk_kwh is
|
||||
'Koeficient měkké penalizace (Kč/kWh krátkého nedodržení) proti předchozímu plánu při rolling replanu.';
|
||||
Reference in New Issue