fix battery charge u self_sustain rezimu
All checks were successful
CI and deploy / migration-check (push) Successful in 3s
CI and deploy / deploy (push) Successful in 25s

This commit is contained in:
Dusan Vojacek
2026-04-19 15:09:33 +02:00
parent 5c868083af
commit efc2cbfded
5 changed files with 51 additions and 4 deletions

View File

@@ -308,6 +308,8 @@ class ControlSetpoints:
effective_sell_price_czk_kwh: float | None = None
#: True = reg 108/109 na 0 (PRESERVE Deye baterii nepoužívá)
lock_battery: bool = False
#: Režim SELF_SUSTAIN: plný rozsah nabíjení/vybíjení na invertoru + zero-export (reg 142) a nízké TOU %.
self_sustain_local_use: bool = False
@dataclass
@@ -1184,6 +1186,7 @@ def _build_setpoints(mode: OperatingModeInfo, pi: asyncpg.Record | None) -> Cont
ev1_power_w=0,
ev2_power_w=0,
target_soc_pct=None,
self_sustain_local_use=True,
)
if code == "CHARGE_CHEAP":
@@ -1291,8 +1294,14 @@ def _deye_passive_tou_battery_soc_pct(
Jinak zůstane provozní podlaha ``min_soc_percent`` (typicky nízká % → přetok do sítě
možný dle chování Deye).
Režim **SELF_SUSTAIN** (``self_sustain_local_use``): vždy ``min_soc_percent`` — nízké
TOU drží prioritu „baterie jako buffer“ při plném reg. 108/109 a reg. 142 zero-export;
neaplikuje se sem logika 100 % podle ceny (LP se v SELF_SUSTAIN nepoužívá).
"""
mn = _deye_tou_min_soc_pct(inv)
if setpoints.self_sustain_local_use:
return mn
bat_w = 0 if setpoints.battery_w is None else int(setpoints.battery_w)
sell = setpoints.effective_sell_price_czk_kwh
@@ -1311,7 +1320,8 @@ def get_deye_mode(setpoints: ControlSetpoints) -> str:
SELL only when battery actively discharges for grid export (bat_w < -500
AND grid_w < -200). Pass-through (PV → grid, battery idle) stays PASSIVE
with reg 108 = 0 + reg 145 = 1 (solar sell).
battery_w=None (SELF_SUSTAIN) → bat_w considered 0 → PASSIVE.
battery_w=None (SELF_SUSTAIN) → bat_w considered 0 → PASSIVE; při exportu se ale
zapíše plný reg. 108/109 (viz ``self_sustain_local_use`` v ``write_inverter_setpoints``).
"""
grid_w = int(setpoints.grid_setpoint_w or 0)
bat_w = 0 if setpoints.battery_w is None else int(setpoints.battery_w)
@@ -1384,6 +1394,11 @@ async def write_inverter_setpoints(
elif deye_mode == "CHARGE":
charge_a = battery_watts_to_amps(bat_w, inv.max_charge_a)
discharge_a = 0
elif setpoints_now.self_sustain_local_use:
# SELF_SUSTAIN: plný nabíjecí i vybíjecí proud invertoru — přebytek FVE jde do baterie,
# reg. 142 = zero export to load/CT (viz selling_mode níže), ne reg. 108 = 0.
charge_a = int(inv.max_charge_a)
discharge_a = int(inv.max_discharge_a)
else:
charge_a = int(inv.max_charge_a) if bat_w > 0 else 0
discharge_a = int(inv.max_discharge_a)