refactor export limit semantics #3

Merged
vojacekd merged 1 commits from refactor-control-monolith into main 2026-05-03 22:29:35 +02:00
16 changed files with 134 additions and 17 deletions

View File

@@ -19,9 +19,6 @@ DEYE_CLOCK_RESYNC_INTERVAL_HOURS = 24
# Deye LV baterie: převod výkon -> proud pro registry 108/109.
BATT_VOLTAGE_V = 51.2
# Reg 143 ve SELL: min(|grid_setpoint_w|, ...) nesmí klesnout pod tuto podlahu (W).
REG143_SELL_CAP_MIN_W = 200
# Reg 178 - bitové pole: bity 4-5 (peak shaving switch) a bity 0-1 (MI export cutoff).
REG178_SELL = 0b00100000
REG178_PASSIVE = 0b00110000

View File

@@ -13,7 +13,6 @@ from services.control.deye_helpers import (
DEYE_TOU_INACTIVE_HHMM,
DEYE_TOU_POWER_REGS,
PRAGUE_TZ,
REG143_SELL_CAP_MIN_W,
REG178_MI_EXPORT_DISABLE,
REG178_MI_EXPORT_ENABLE,
REG178_MI_EXPORT_MASK,

View File

@@ -15,7 +15,6 @@ from services.control.deye_helpers import (
DEYE_CLOCK_RESYNC_INTERVAL_HOURS,
DEYE_TOU_INACTIVE_HHMM,
PRAGUE_TZ,
REG143_SELL_CAP_MIN_W,
REG178_MI_EXPORT_DISABLE,
REG178_MI_EXPORT_ENABLE,
REG178_MI_EXPORT_MASK,
@@ -103,8 +102,6 @@ async def write_inverter_setpoints(
selling_mode = 0 if deye_mode == "SELL" else zero_exp_mode
solar_sell = 0 if (setpoints_now.export_ban and deye_mode != "SELL") else 1
export_limit = export_lim
if deye_mode == "SELL" and grid_w < 0:
export_limit = min(export_lim, max(REG143_SELL_CAP_MIN_W, abs(grid_w)))
reg178_val = REG178_SELL if deye_mode == "SELL" else REG178_PASSIVE
logger.info(

View File

@@ -39,6 +39,7 @@ class InverterConfig:
@dataclass
class ControlSetpoints:
battery_w: int | None
#: Tvrdý limit exportu do sítě v daném slotu (W), ne forecastová cílová hodnota.
grid_export_limit: int
ev1_current_a: int
ev2_current_a: int

View File

@@ -81,6 +81,8 @@ def _build_setpoints(
if pi is None:
return None
grid_sp = int(pi["grid_setpoint_w"] or 0)
export_limit_raw = pi.get("export_limit_w")
export_limit = int(export_limit_raw) if export_limit_raw is not None else abs(min(grid_sp, 0))
ev1_w = int(pi["ev1_setpoint_w"] or 0) if "ev1_setpoint_w" in pi else 0
ev2_w = int(pi["ev2_setpoint_w"] or 0) if "ev2_setpoint_w" in pi else 0
hp_en = bool(pi["heat_pump_enabled"])
@@ -90,6 +92,10 @@ def _build_setpoints(
pm: str | None = str(pm_raw).strip().upper() if pm_raw is not None else None
sell_raw = pi.get("effective_sell_price")
sell_f: float | None = float(sell_raw) if sell_raw is not None else None
export_mode_raw = pi.get("export_mode")
export_mode = str(export_mode_raw).strip().upper() if export_mode_raw is not None else None
if export_mode == "NONE":
export_limit = 0
# Záporný výkup sám o sobě neblokuje export, pokud plán export explicitně žádá.
export_ban = sell_f is not None and float(sell_f) < 0 and grid_sp >= 0
gen_cutoff_raw = pi.get("deye_gen_cutoff_enabled")
@@ -112,7 +118,7 @@ def _build_setpoints(
pv_a_allowed = 0
return ControlSetpoints(
battery_w=int(pi["battery_setpoint_w"] or 0),
grid_export_limit=abs(min(grid_sp, 0)),
grid_export_limit=max(0, export_limit),
ev1_current_a=watts_to_amps(ev1_w, phases=3),
ev2_current_a=watts_to_amps(ev2_w, phases=1),
heat_pump_enable=hp_en,

View File

@@ -319,6 +319,8 @@ class DispatchResult:
battery_setpoint_w: int # kladné = nabíjení, záporné = vybíjení
battery_soc_target: float # % SoC na konci intervalu
grid_setpoint_w: int # kladné = import, záporné = export
export_limit_w: int # tvrdý limit exportu do sítě; 0 = bez exportu
export_mode: str # NONE / PV_SURPLUS / BATTERY_SELL
#: Explicitní fyzický režim Deye pro control exporter (PASSIVE / SELL / CHARGE).
#: Cíl: odstranit heuristiky z exporteru a nést záměr přímo v plánu.
deye_physical_mode: str
@@ -851,6 +853,10 @@ def solve_dispatch(
batt_w = round(pulp.value(bc[t]) - pulp.value(bd[t]))
grid_w = round(pulp.value(gi[t]) - pulp.value(ge[t]))
soc_pct = round(pulp.value(soc[t]) / battery.usable_capacity_wh * 100, 1)
export_limit_w = int(grid.max_export_power_w) if grid_w < 0 else 0
export_mode = "NONE"
if grid_w < 0:
export_mode = "BATTERY_SELL" if batt_w < 0 else "PV_SURPLUS"
# Primární klasifikace fyzického režimu pro Deye: explicitně do plánu (Variant A).
# Default PASSIVE; SELL při export+vybíjení; CHARGE při import+nabíjení.
@@ -874,6 +880,8 @@ def solve_dispatch(
battery_setpoint_w = batt_w,
battery_soc_target = soc_pct,
grid_setpoint_w = grid_w,
export_limit_w = export_limit_w,
export_mode = export_mode,
deye_physical_mode = deye_mode,
deye_gen_cutoff_enabled = deye_gen_cutoff,
ev1_setpoint_w = round(pulp.value(ev_direct[0][t]) + pulp.value(ev_via_bat[0][t]))
@@ -1319,6 +1327,8 @@ async def _save_planning_run(
"battery_setpoint_w": r.battery_setpoint_w,
"battery_soc_target_pct": r.battery_soc_target,
"grid_setpoint_w": r.grid_setpoint_w,
"export_limit_w": r.export_limit_w,
"export_mode": r.export_mode,
"deye_physical_mode": r.deye_physical_mode,
"deye_gen_cutoff_enabled": r.deye_gen_cutoff_enabled,
"ev1_setpoint_w": r.ev1_setpoint_w,

View File

@@ -178,6 +178,10 @@ async def compute_export_ban_active(site_id: int, conn: asyncpg.Connection) -> b
if bool(pi.get("is_predicted_price")):
return True
export_mode = str(pi.get("export_mode") or "").upper()
if export_mode in ("PV_SURPLUS", "BATTERY_SELL"):
return False
sell_raw = pi.get("effective_sell_price")
grid_sp = int(pi.get("grid_setpoint_w") or 0)
if sell_raw is None:

View File

@@ -15,6 +15,8 @@ from services.control.exporter_monolith import (
deye_reg_triggers_self_sustain_after_verify_exhaust,
get_deye_mode,
)
from services.control.models import OperatingModeInfo
from services.control.setpoints import _build_setpoints
def _inv(*, min_soc: int | None = 12, reserve_soc: int | None = 20) -> InverterConfig:
@@ -110,6 +112,30 @@ class DeyeTouParamsTests(unittest.TestCase):
)
self.assertEqual(get_deye_mode(sp), "PASSIVE")
def test_build_setpoints_uses_explicit_export_limit(self) -> None:
mode = OperatingModeInfo(
mode_code="AUTO",
battery_mode="AUTO",
grid_mode="AUTO",
ev_enabled=False,
heat_pump_enabled_def=False,
loxone_mode_value=1,
)
pi = {
"battery_setpoint_w": 0,
"grid_setpoint_w": -3000,
"export_limit_w": 13_500,
"export_mode": "PV_SURPLUS",
"ev1_setpoint_w": 0,
"ev2_setpoint_w": 0,
"heat_pump_enabled": False,
"battery_soc_target_pct": 50,
"effective_sell_price": 1.0,
}
sp = _build_setpoints(mode, pi)
self.assertIsNotNone(sp)
self.assertEqual(sp.grid_export_limit, 13_500)
def test_pv_led_export_with_small_battery_is_sell(self) -> None:
"""Obě záporné → SELL (bez porovnání |bat| vs |grid|)."""
sp = ControlSetpoints(

View File

@@ -254,6 +254,47 @@ class PlanningDispatchMilpTests(unittest.TestCase):
self.assertEqual(int(results[0].pv_a_curtailed_w), 5000)
self.assertGreaterEqual(int(results[0].grid_setpoint_w), 0)
def test_pv_surplus_export_uses_hard_export_cap(self) -> None:
slots = [
_slot(load=0, buy=3.0, sell=2.5, pv_a=20_000, pv_b=0),
]
battery = _battery()
hp = SimpleNamespace(
rated_heating_power_w=0,
tuv_min_temp_c=45.0,
tuv_target_temp_c=55.0,
)
grid = SimpleNamespace(max_import_power_w=20_000, max_export_power_w=13_500)
vehicles = [
SimpleNamespace(
max_charge_power_w=0,
battery_capacity_kwh=1.0,
default_target_soc_pct=80.0,
),
SimpleNamespace(
max_charge_power_w=0,
battery_capacity_kwh=1.0,
default_target_soc_pct=80.0,
),
]
soc0 = battery.soc_max_wh
results, _ms = solve_dispatch(
slots,
battery,
hp,
grid,
[None, None],
vehicles,
soc0,
50.0,
tuv_delta_stats=None,
operating_mode="AUTO",
)
self.assertEqual(len(results), 1)
self.assertEqual(results[0].export_mode, "PV_SURPLUS")
self.assertEqual(results[0].export_limit_w, 13_500)
self.assertGreater(results[0].pv_a_curtailed_w, 0)
def test_two_tier_soc_solves_optimal(self) -> None:
slots = [_slot()]
battery = _battery()

View File

@@ -152,7 +152,7 @@ bits 01). Detail registrů: [`modbus-registers.md`](modbus-registers.md) (reg
| **CHARGE** | `battery_w` > 0 **a** `grid_setpoint_w` > 0 |
| **PASSIVE (ZERO)** | vše ostatní — reg. **108/109** dle `_deye_zero_export_amps_for_passive` (viz `operating-modes.md`) |
**PASSIVE** (AUTO, ZERO): výchozí **108** i **109** = maximum z DB; u exportu bez vybíjení **108 = 0**, u importu bez nabíjení **109 = 0** (`_deye_zero_export_amps_for_passive`). **TOU** z plánu. Reg. **142** = `deye_zero_export_mode`. Reg. **145** (solar sell): **0** při `export_ban` mimo SELL, jinak **1** — význam přepínače a rozdíl vůči neřízeným FVE polím je v [`operating-modes.md`](operating-modes.md) (sekce *ZERO a zakázaný export*).
**PASSIVE** (AUTO, ZERO): výchozí **108** i **109** = maximum z DB; u exportu bez vybíjení **108 = 0**, u importu bez nabíjení **109 = 0** (`_deye_zero_export_amps_for_passive`). **TOU** z plánu. Reg. **142** = `deye_zero_export_mode`. Reg. **143** je tvrdý limit exportu z lokality/invertoru (ne forecast). Reg. **145** (solar sell): **0** při `export_ban` mimo SELL, jinak **1** — význam přepínače a rozdíl vůči neřízeným FVE polím je v [`operating-modes.md`](operating-modes.md) (sekce *ZERO a zakázaný export*).
**SELF_SUSTAIN** zůstává **PASSIVE** v `get_deye_mode`; **108/109** jsou vždy **max z DB** (bez variant ZERO). Rozdíl je **`self_sustain_local_use=True`**: **TOU SOC** = **`min_soc_percent`**, `battery_w=None`.
@@ -163,7 +163,7 @@ bits 01). Detail registrů: [`modbus-registers.md`](modbus-registers.md) (reg
| **108** (charge A) | škálo dle `battery_w` | max / **0** (FVE přetok) | **0** | dle varianty |
| **109** (discharge A) | **0** | max / **0** (import, držet bat.) | **max z DB** | dle varianty |
| **142** (limit control) | `deye_zero_export_mode` | `deye_zero_export_mode` | **0** (selling first) | `deye_zero_export_mode` |
| **143** (export cap) | max z DB | max z DB | `min(max_site, max(200, \|grid_setpoint_w\|))` | max z DB |
| **143** (export cap) | max z DB | max z DB | max z DB (tvrdý limit, bez forecast heuristiky) | max z DB |
| **145** (solar sell) | 1 / 0 při `export_ban` | 1 / 0 při `export_ban` | 1 | 1 / 0 při `export_ban` |
| **178** (peak shaving) | 48 | 48 | **32** | 48 |
@@ -207,7 +207,7 @@ async def write_inverter_setpoints(site_id: int, setpoints: Setpoints, db):
slave=inv.unit_id)
# Export limit
export_limit = max(0, -setpoints.grid_setpoint_w) if setpoints.grid_setpoint_w < 0 else 0
export_limit = setpoints.grid_export_limit
await client.write_register(0x00F6, export_limit, slave=inv.unit_id)
logger.info(f"Inverter {inv.code} setpoints written: batt={setpoints.battery_setpoint_w}W")

View File

@@ -20,7 +20,7 @@ EMS zapisuje řídící hodnoty přes journal (`modbus_command`) a **`write_regi
| 142 | Limit control (System work mode) | 0/1/2 | — | **0** = selling first, **1** = zero export to load, **2** = zero export to CT. Hodnota v non-SELL režimech pochází z `asset_inverter.deye_zero_export_mode` (závisí na instalaci viz tabulka níže). V režimu SELL vždy **0**. |
| 145 | Solar sell | 0/1 | — | **0** = disabled (přebytek FVE na **straně měniče** se nesmí vést do sítě — curtailment vůči síti), **1** = enabled. Platí jen pro **FVE pod kontrolou Deye** (`controllable = true`); druhá pole (např. **pv-b** u home-01) EMS tímto registerem neřídí. EMS dnes **vždy zapisuje 1**; při 108 = 0 a 145 = 1 přebytky z řiditelného stringu typicky tečou do sítě (viz pass-through níže). |
| 340 | Max solar power | 0 … cap (W) | 1 W | Strop výkonu DC PV řízeného střídačem (pole A). EMS zapisuje jen pokud `ems.fn_site_has_active_green_bonus_pv(site_id)` (zelený bonus na PV poli) **a** `ems.fn_inverter_pv_a_max_w(inverter_id) > 0`. Hodnota z aktivního `planning_interval`: bez curtailmentu = cap; s `pv_a_curtailed_w > 0` = `clamp(0, cap, pv_a_forecast_solver_w pv_a_curtailed_w)`. **Není** v `DEYE_CRITICAL_REGS_SELF_SUSTAIN` — verify mismatch nečeká přepnutí do SELF_SUSTAIN. |
| 143 | Export limit W | závisí na typu (SUN-20K až ~13 500) | 1 W | Max export do sítě; hodnota z `site_grid_connection.max_export_power_w` |
| 143 | Export limit W | závisí na typu (SUN-20K až ~13 500) | 1 W | Max export do sítě; hodnota z `site_grid_connection.max_export_power_w`. EMS ji neodvozuje z forecastu ani z `grid_setpoint_w`; pro exportní sloty je to tvrdý site/inverter cap. |
| 178 | Control board special 1 | bitmask | — | Bitové pole pro více funkcí. **EMS používá:** (a) bits **45** pro peak shaving switch: **32** (`0b00100000`, bit45 = **10**) v režimu **SELL**; **48** (`0b00110000`, bit45 = **11**) v **PASSIVE/CHARGE**. (b) **BA81:** bits **01** pro „MI export to Grid cutoff“ (AC coupling / GEN): **2** = disable (cutoff OFF), **3** = enable (cutoff ON). EMS zapisuje jako **read-modify-write** (zachová ostatní bity). V některých manuálech/UI je to označené jako „register 179“ (1-based). |
| 190 | GEN peak shaving | 016000 | 1 W | Peak shaving na GEN portu |
| 191 | Grid peak shaving power | 016000 | 1 W | **EMS NEZAPISUJE** nastavit **manuálně v SolarmanApp**. Hodnota určuje výkon peak shavingu v **W**. |

View File

@@ -3,6 +3,7 @@
## Keep it simple
- **Žádné wattové prahy pro výběr SELL / CHARGE** — mapování z MILP setpointů je čistě ze **znamének** `battery_setpoint_w` a `grid_setpoint_w` (viz `get_deye_mode` v `exporter_monolith.py`).
- **Přetok FVE do sítě** se neodvozuje z forecastového capu: plán nese explicitní `export_limit_w` jako tvrdý limit lokality / invertoru, ne jako tipované maximum z předpovědi.
- **ZERO (PASSIVE)** = zero export k CT/zátěži (**142** = `deye_zero_export_mode`), s **plnými proudy 108/109** jen ve výchozím stavu; pro přetok FVE do sítě nebo odběr ze sítě bez vybíjení baterie se jeden z proudů **vynuluje** (`_deye_zero_export_amps_for_passive`).
- **SELL** = plánovaný export **i** plánované vybíjení (oba záporné) → **142** = selling first, **178** = vypnutý grid peak shaving (32); po návratu do ZERO/CHARGE zase **178** = 48.
- Novou logiku vždy ověřit proti **reálnému řádku plánu** (audit / `planning_interval`).
@@ -54,6 +55,8 @@ Všechny řádky předpokládají **142** = zero export (ne SELL).
| Přetok FVE do sítě | `grid_setpoint_w` < 0 **a** `battery_w` ≥ 0 | **0** | max |
| Držet baterii, brát ze sítě | `grid_setpoint_w` > 0 **a** `battery_w` ≤ 0 | max | **0** |
V obou exportních případech platí, že `export_limit_w` je **tvrdý site/inverter cap**. Nejde o forecastový odhad exportu, takže se může pustit plný přetok v rámci distribučního limitu.
Nabíjení ze sítě s vysokým cílovým SoC v TOU řeší větev **CHARGE** (grid charge v time pointech), ne tato tabulka.
### ZERO a „zakázaný export FVE do sítě“ (jen řiditelná pole)

View File

@@ -30,6 +30,7 @@
- **Záporná prodejní cena → tvrdý zákaz vývozu (`ge = 0`)** (`planning_engine.solve_dispatch`): platí ve slotu kde `sell_price < 0`, pokud lokality zapne některou z opcí —
- **`asset_inverter.deye_gen_microinverter_cutoff_enabled`** (`deye-main`) — spojeno s MILP binárkami GEN cut-off (BA81),
- **nebo** **`ems.site_grid_connection.block_export_on_negative_sell`** (migrace **V074**, default **false**) — bez GEN registrů na Deye; vhodné např. pro **KV1** (fixní nákup, bez nutnosti vést výkon neriťitelného pole B do sítě). **home-01** nech **false**, jinak může být horizont při přebytku z pole B a plné/nedostupné baterii **infeasible** (solver export potřebuje jako fyzikální ventil tam, kde FVE B nelze štípnout ani odpojit modelem bez GEN řádku).
- **Export bez forecastového capu:** solver ukládá explicitní `planning_interval.export_limit_w` jako tvrdý site/inverter limit a `planning_interval.export_mode` (`NONE` / `PV_SURPLUS` / `BATTERY_SELL`). Exportér z plánu neodvozuje žádný forecastový strop exportu.
- **Uložené vstupy plánu** (`planning_interval`): `load_baseline_w`, `pv_*_forecast_raw_w`, `pv_*_forecast_solver_w` pro UI a audit.
- **Více FVE polí s různou orientací:** `planning_engine._load_slots` sčítá predikovaný výkon za 15min přes **všechna** `asset_pv_array` dané lokality — `pv_a_forecast_w` = součet řádků s `controllable = true`, `pv_b_forecast_w` = součet s `controllable = false`. Pro každé pole a slot se bere **nejnovější** `forecast_pv_run` (`ORDER BY created_at DESC`, `DISTINCT ON (pv_array_id)`). Curtailment v LP zůstává **jedno** agregované `pv_a` (součet řiditelných polí); per-string curtailment by vyžadovalo rozšíření modelu.
- **Kalibrace PV forecastu (delta profil):** tabulka `ems.site_pv_forecast_calibration` drží per `site_id` mimo jiné `delta_learn_min_ts` (dolní mez řádků z `forecast_accuracy` pro učení delty), volitelně `pv_curtailment_policy_effective_from` a přepsání parametrů (`top_n_days`, `half_life_days`, …; **V076** navíc `reference_day_weight_mult` pro „připnuté“ dny níže). **`ems.site_pv_forecast_reference_day`** (**V076**) umožňuje zvýšit váhu konkrétních kalendářních dnů (datum ve `site.timezone` jako u časování slotů) při agregaci δ z `forecast_accuracy` (`fn_pv_forecast_delta_profile`); hromadný zápis **`ems.fn_pv_forecast_sync_reference_days`**, detail **`docs/04-modules/forecast.md`**. `ems.fn_fill_forecast_accuracy` nastavuje `learning_eligible` / `learning_exclude_reason` (sloty před cutoffem, nebo se škrcením / gen cut-off / záznamem v `ems.cutoff_switch_log` po účinnosti policy se z učení vyřadí; u škrcení zůstává `actual_power_w` NULL). Telemetrie: `ems.telemetry_inverter.is_export_limited` nebo `pv_derating_flags <> 0` v okně 15min → stejné vyloučení (`telemetry_derating`). `ems.fn_pv_forecast_delta_profile` vrací `deltas_by_array` i součtové `deltas`; `ems.fn_load_planning_slots_full` aplikuje stejnou **per-pole** korekci jako UI (`fn_forecast_pv_slots_range_corrected`); pokud v JSON profilu chybí `deltas_by_array`, použije se souhrnné `deltas` rozpuštěné podle podílu výkonu pole na slotu (solver má tak stále použitou korekci i bez per-pole JSON).
@@ -421,6 +422,8 @@ def solve_dispatch(
battery_setpoint_w = round(pulp.value(batt_charge[t]) - pulp.value(batt_discharge[t])),
battery_soc_target = round(pulp.value(soc[t]) / battery.usable_capacity_wh * 100, 1),
grid_setpoint_w = round(pulp.value(grid_import[t]) - pulp.value(grid_export[t])),
export_limit_w = int(grid.max_export_power_w) if round(pulp.value(grid_import[t]) - pulp.value(grid_export[t])) < 0 else 0,
export_mode = "BATTERY_SELL" if round(pulp.value(batt_charge[t]) - pulp.value(batt_discharge[t])) < 0 and round(pulp.value(grid_import[t]) - pulp.value(grid_export[t])) < 0 else ("PV_SURPLUS" if round(pulp.value(grid_import[t]) - pulp.value(grid_export[t])) < 0 else "NONE"),
ev_charge_power_w = round(pulp.value(ev_charge[t])),
heat_pump_enabled = hp_enabled,
heat_pump_setpoint_w = hp_power,

View File

@@ -84,6 +84,12 @@ const LiveRegistersSection = memo(
valueText={live?.reg142_limit_control != null ? String(live.reg142_limit_control) : undefined}
/>
<Metric label="Energy mode" reg={141} valueText={live?.reg141_energy_mode != null ? String(live.reg141_energy_mode) : undefined} />
<Metric
label="Export cap"
reg={143}
sub="Hard limit lokality / invertoru; neforecastuje se"
valueText={fmtW(live?.reg143_export_limit_w)}
/>
<Metric
label="Peak shaving switch"
reg={178}

View File

@@ -221,6 +221,8 @@ function syntheticForecastOnlyInterval(
battery_setpoint_w: null,
battery_soc_target_pct: null,
grid_setpoint_w: null,
export_limit_w: null,
export_mode: null,
deye_physical_mode: null,
ev1_setpoint_w: null,
ev2_setpoint_w: null,
@@ -341,6 +343,7 @@ function axiosDetail(e: unknown): string {
function deyeSetpointLabel(i: PlanningIntervalDto): string {
const battery_w = i.battery_setpoint_w ?? 0
const grid_w = i.grid_setpoint_w ?? 0
const exportLimitW = i.export_limit_w ?? 0
const tgt = i.battery_soc_target_pct
const targetSoc = tgt != null ? Math.min(95, Math.round(Number(tgt))) : 80
@@ -353,14 +356,18 @@ function deyeSetpointLabel(i: PlanningIntervalDto): string {
const pm = (i.deye_physical_mode ?? '').toString().trim().toUpperCase()
if (pm === 'SELL') {
const tpPowerW = Math.abs(battery_w)
return `SELL | ⬇ ${fmtKw(tpPowerW)} | reg142=0 reg178=32`
const cap = exportLimitW > 0 ? ` | cap ${fmtKw(exportLimitW)}` : ''
return `SELL | ⬇ ${fmtKw(tpPowerW)}${cap} | reg142=0 reg178=32`
}
if (pm === 'CHARGE') {
return `CHARGE | ⬆ ${fmtKw(Math.max(0, battery_w))} | grid=yes | SOC→${targetSoc}%`
}
// PASSIVE (ZERO): doplň informaci o variantě 108/109 podle pravidel (bez wattových prahů).
if (grid_w < 0 && battery_w >= 0) return 'PASSIVE | FVE→síť (108=0)'
if (grid_w < 0 && battery_w >= 0) {
const cap = exportLimitW > 0 ? ` | cap ${fmtKw(exportLimitW)}` : ''
return `PASSIVE | FVE→síť${cap} (108=0)`
}
if (grid_w > 0 && battery_w <= 0) return 'PASSIVE | držet bat. (109=0)'
return 'PASSIVE | max/max'
}
@@ -369,12 +376,15 @@ function deyeModeBadge(i: PlanningIntervalDto): { label: string; klass: string;
const m = (i.deye_physical_mode ?? 'PASSIVE').toString().trim().toUpperCase()
const battery_w = i.battery_setpoint_w ?? 0
const grid_w = i.grid_setpoint_w ?? 0
const exportLimitW = i.export_limit_w ?? 0
const exportMode = (i.export_mode ?? 'NONE').toString().trim().toUpperCase()
const cap = exportLimitW > 0 ? `; hard cap ${formatPlanPowerW(exportLimitW)}` : ''
if (m === 'SELL') {
return {
label: 'SELL',
klass: 'bg-orange-500/15 text-orange-200 ring-1 ring-orange-500/35',
title: 'SELL (selling first): reg142=0, reg178=32 (grid peak shaving off)',
title: `SELL (selling first): reg142=0, reg178=32 (grid peak shaving off)${cap}`,
}
}
if (m === 'CHARGE') {
@@ -386,12 +396,14 @@ function deyeModeBadge(i: PlanningIntervalDto): { label: string; klass: string;
}
let variant = 'max/max'
if (grid_w < 0 && battery_w >= 0) variant = 'FVE→síť (108=0)'
if (grid_w < 0 && battery_w >= 0) {
variant = exportMode === 'PV_SURPLUS' ? 'FVE→síť' : 'export'
}
else if (grid_w > 0 && battery_w <= 0) variant = 'držet bat. (109=0)'
return {
label: 'PASSIVE',
klass: 'bg-slate-600/40 text-slate-200 ring-1 ring-slate-500/30',
title: `PASSIVE (ZERO): ${variant}; reg142=deye_zero_export_mode; reg178=48`,
title: `PASSIVE (ZERO): ${variant}${cap}; reg142=deye_zero_export_mode; reg178=48`,
}
}
@@ -539,6 +551,8 @@ function PlanTooltip({
const fveStr = formatPlanPowerW(p.pv_a_w)
const fveDisplay = fveStr === '—' ? '—' : fveStr.includes('kW') ? fveStr : `${fveStr} W`
const soc = p.battery_soc_target_pct
const exportLimit = i.export_limit_w
const exportMode = i.export_mode ?? 'NONE'
return (
<div className="rounded-lg border border-slate-600 bg-slate-950 px-3 py-2 text-xs text-slate-200 shadow-xl">
<div className="mb-1 font-medium text-slate-100">{formatLocal(i.interval_start)}</div>
@@ -556,6 +570,12 @@ function PlanTooltip({
{sell != null ? `${sell.toFixed(3)} Kč/kWh` : '—'}
</div>
<div>FVE (korig. předpověď / audit): {fveDisplay}</div>
{exportMode !== 'NONE' ? (
<div>
Export: {exportMode}
{exportLimit != null ? ` · limit ${formatPlanPowerW(exportLimit)}` : ''}
</div>
) : null}
<div>SoC cíl: {soc != null && !Number.isNaN(Number(soc)) ? `${Number(soc).toFixed(1)} %` : '—'}</div>
<div>Dům: {i.load_baseline_w ?? '—'} W</div>
<div>Baterie: {i.battery_setpoint_w ?? '—'} W</div>

View File

@@ -15,6 +15,10 @@ export type PlanningIntervalDto = {
battery_setpoint_w: number | null
battery_soc_target_pct: number | null
grid_setpoint_w: number | null
/** Tvrdý limit exportu do sítě v daném slotu (W); 0 = bez exportu. */
export_limit_w?: number | null
/** Záměr exportu: NONE / PV_SURPLUS / BATTERY_SELL. */
export_mode?: 'NONE' | 'PV_SURPLUS' | 'BATTERY_SELL' | null
/** Explicitní fyzický režim Deye pro slot (PASSIVE/SELL/CHARGE). */
deye_physical_mode?: 'PASSIVE' | 'SELL' | 'CHARGE' | null
/** True = solver plánuje odpojit GEN port (MI export cutoff) v tomto slotu (BA81). */