"""Top-level control export orchestration.""" from __future__ import annotations import logging import asyncpg from services.control.inverter import write_inverter_setpoints from services.control.models import ControlSetpoints from services.control.outputs import ( send_loxone_setpoints, write_ev_setpoints, write_heat_pump_setpoint, ) from services.control.repository import ( _fetch_max_charge_power_w, _fetch_operating_mode, _fetch_plan_row_for_slot_offset, _load_inverter_config, ) from services.control.setpoints import _apply_price_failsafe_guard, _build_setpoints from services.signal_service import enqueue_site_signals logger = logging.getLogger(__name__) async def export_setpoints(site_id: int, db: asyncpg.Connection) -> None: mode = await _fetch_operating_mode(site_id, db) if mode is None: logger.warning("control export site=%s: no operating mode row", site_id) return if mode.mode_code == "MANUAL": logger.info("control export site=%s: MANUAL, skip writes", site_id) return try: inv_for_pv = await _load_inverter_config(site_id, db) cap_pv = int(inv_for_pv.pv_a_cap_w) if inv_for_pv is not None else 0 min_pv = int(inv_for_pv.pv_a_reg340_min_w) if inv_for_pv is not None else 0 reg340_en = ( bool(inv_for_pv.deye_reg340_pv_a_control_enabled) if inv_for_pv is not None else False ) pi_now = await _fetch_plan_row_for_slot_offset(site_id, db, 0) pi_next = await _fetch_plan_row_for_slot_offset(site_id, db, 1) sp_now = _build_setpoints( mode, pi_now, pv_a_cap_w=cap_pv, pv_a_reg340_min_w=min_pv, reg340_pv_a_control_enabled=reg340_en, ) sp_next = _build_setpoints( mode, pi_next, pv_a_cap_w=cap_pv, pv_a_reg340_min_w=min_pv, reg340_pv_a_control_enabled=reg340_en, ) if mode.mode_code == "AUTO" and sp_now is None: if pi_now is None: logger.warning( "control export site=%s: AUTO but no planning_interval for current slot, skip", site_id, ) return if sp_now is None: logger.warning( "control export site=%s: no setpoints for mode %s, skip", site_id, mode.mode_code, ) return if mode.mode_code == "CHARGE_CHEAP": max_ch = await _fetch_max_charge_power_w(site_id, db) pw = max(1, int(max_ch)) sp_now = ControlSetpoints( battery_w=pw, grid_export_limit=0, ev1_current_a=0, ev2_current_a=0, heat_pump_enable=False, grid_setpoint_w=pw, ev1_power_w=0, ev2_power_w=0, target_soc_pct=None, effective_sell_price_czk_kwh=None, ) sp_next = sp_now else: sp_now = _apply_price_failsafe_guard(site_id, mode, pi_now, sp_now) if sp_next is not None: sp_next = _apply_price_failsafe_guard(site_id, mode, pi_next, sp_next) planning_run_id = await db.fetchval( """ SELECT id FROM ems.planning_run WHERE site_id = $1 AND status = 'active' ORDER BY created_at DESC LIMIT 1 """, site_id, ) if planning_run_id is not None: planning_run_id = int(planning_run_id) try: inv_res = await write_inverter_setpoints( site_id, sp_now, sp_next, db, planning_run_id=planning_run_id ) except Exception as e: logger.error("inverter write failed: %s", e) inv_res = f"FAIL inverter: {e}" try: ev_res = await write_ev_setpoints(site_id, sp_now, db) except Exception as e: logger.error("ev write failed: %s", e) ev_res = f"FAIL ev: {e}" try: hp_res = await write_heat_pump_setpoint(site_id, sp_now, db) except Exception as e: logger.error("hp write failed: %s", e) hp_res = f"FAIL heat pump: {e}" try: lox_res = await send_loxone_setpoints(site_id, sp_now, mode, db) except Exception as e: logger.error("loxone write failed: %s", e) lox_res = f"FAIL Loxone: {e}" results = list( zip( ("inverter", "ev", "heat_pump", "loxone"), (inv_res, ev_res, hp_res, lox_res), ) ) for name, res in results: if isinstance(res, Exception): logger.error("control export site=%s %s: FAIL %s", site_id, name, res) elif isinstance(res, str) and res.startswith("FAIL"): logger.error("control export site=%s %s: %s", site_id, name, res) else: logger.info("control export site=%s %s: %s", site_id, name, res) finally: try: await enqueue_site_signals(site_id, db) except Exception as e: logger.warning( "control export site=%s: signal enqueue failed: %s", site_id, e )