-- R__vw_latest_telemetry.sql
-- EMS Platform aktuální stav všech zařízení per lokalita
-- Repeatable migration
-- =============================================================
CREATE OR REPLACE VIEW ems.vw_latest_inverter AS
SELECT DISTINCT ON (t.inverter_id)
t.site_id,
t.inverter_id,
inv.code AS inverter_code,
t.measured_at,
t.pv_power_w,
t.battery_soc_percent,
t.battery_power_w,
t.grid_power_w,
t.load_power_w,
t.inverter_temp_c,
t.operating_mode,
t.fault_code,
now() - t.measured_at AS data_age,
t.pv1_power_w,
t.pv2_power_w,
t.gen_port_power_w,
t.batt_charge_today_wh,
t.batt_discharge_today_wh,
t.run_state
FROM ems.telemetry_inverter t
JOIN ems.asset_inverter inv ON inv.id = t.inverter_id
ORDER BY t.inverter_id, t.measured_at DESC;
COMMENT ON VIEW ems.vw_latest_inverter IS
'Nejnovější telemetrická data pro každý střídač. Slouží pro real-time dashboard a health check.';
-- ------------------------------------------------------------
CREATE OR REPLACE VIEW ems.vw_latest_ev_charger AS
SELECT DISTINCT ON (t.charger_id, t.connector_id)
t.site_id,
t.charger_id,
ch.code AS charger_code,
t.connector_id,
t.measured_at,
t.status,
t.power_w,
t.energy_kwh,
t.current_a,
t.session_id,
t.error_code,
now() - t.measured_at AS data_age
FROM ems.telemetry_ev_charger t
JOIN ems.asset_ev_charger ch ON ch.id = t.charger_id
ORDER BY t.charger_id, t.connector_id, t.measured_at DESC;
COMMENT ON VIEW ems.vw_latest_ev_charger IS
'Nejnovější telemetrická data pro každý konektor EV nabíječky. Slouží pro dashboard a řízení nabíjení.';
-- ------------------------------------------------------------
CREATE OR REPLACE VIEW ems.vw_latest_heat_pump AS
SELECT DISTINCT ON (t.heat_pump_id)
t.site_id,
t.heat_pump_id,
hp.code AS heat_pump_code,
t.measured_at,
t.outdoor_temp_c,
t.tuv_tank_temp_c,
t.water_outlet_temp_c,
t.power_w,
t.operating_mode,
t.cop_actual,
t.defrost_active,
t.alarm_code,
-- Odhadovaný COP pro aktuální venkovní teplotu
ems.fn_cop_estimate(t.heat_pump_id, t.outdoor_temp_c) AS cop_estimated,
now() - t.measured_at AS data_age
FROM ems.telemetry_heat_pump t
JOIN ems.asset_heat_pump hp ON hp.id = t.heat_pump_id
ORDER BY t.heat_pump_id, t.measured_at DESC;
COMMENT ON VIEW ems.vw_latest_heat_pump IS
'Nejnovější telemetrická data pro každé tepelné čerpadlo včetně odhadovaného COP.
Slouží pro real-time dashboard a rozhodovací logiku plánování.';