"""Export plánovaných setpointů na Modbus (Deye, EV, TČ) a HTTP do Loxone."""
|
||
|
||
from __future__ import annotations
|
||
|
||
import logging
|
||
from datetime import datetime, timezone
|
||
from typing import Any
|
||
|
||
import asyncpg
|
||
|
||
from services.control.deye_helpers import (
|
||
BATT_VOLTAGE_V,
|
||
DEYE_CLOCK_DRIFT_OK_SEC,
|
||
DEYE_CLOCK_REGS,
|
||
DEYE_CLOCK_RESYNC_INTERVAL_HOURS,
|
||
DEYE_CLOCK_VERIFY_MAX_DELTA_SEC, # noqa: F401 - re-export for compatibility
|
||
DEYE_CRITICAL_REGS_SELF_SUSTAIN, # noqa: F401 - re-export for compatibility
|
||
DEYE_REGISTER_NAMES, # noqa: F401 - re-export for compatibility
|
||
DEYE_TOU_INACTIVE_HHMM,
|
||
DEYE_TOU_POWER_REGS,
|
||
PRAGUE_TZ,
|
||
REG143_SELL_CAP_MIN_W,
|
||
REG178_MI_EXPORT_DISABLE,
|
||
REG178_MI_EXPORT_ENABLE,
|
||
REG178_MI_EXPORT_MASK,
|
||
REG178_PASSIVE,
|
||
REG178_SELL,
|
||
REG178_VERIFY_MASK,
|
||
REG178_VERIFY_MASK_COMBINED,
|
||
_DEYE_INACTIVE_TOU_REGISTERS,
|
||
_deye_clock_registers_verify_match,
|
||
_deye_reg178_verify_match,
|
||
_deye_reg178_verify_with_double_read,
|
||
_deye_registers_to_prague_datetime, # noqa: F401 - re-export for compatibility
|
||
_deye_should_skip_time_sync_after_read,
|
||
_deye_tou_power_verify_match,
|
||
_prague_minute_start_utc,
|
||
battery_watts_to_amps,
|
||
compute_pv_a_reg340_max_solar_w,
|
||
current_slot_hhmm,
|
||
deye_reg_triggers_self_sustain_after_verify_exhaust, # noqa: F401 - re-export
|
||
next_slot_hhmm,
|
||
watts_to_amps,
|
||
)
|
||
from services.control.models import ControlSetpoints, InverterConfig, OperatingModeInfo
|
||
from services.control.modbus_journal import (
|
||
_drop_registers_matching_last_verified,
|
||
_fetch_last_verified_inverter_registers,
|
||
create_modbus_commands,
|
||
execute_modbus_commands,
|
||
)
|
||
from services.control.outputs import (
|
||
_current_limit_for_charger,
|
||
send_loxone_setpoints,
|
||
write_ev_setpoints,
|
||
write_heat_pump_setpoint,
|
||
)
|
||
from services.control.repository import (
|
||
_fetch_max_charge_power_w,
|
||
_fetch_operating_mode,
|
||
_fetch_plan_row_for_slot_offset,
|
||
_get_current_soc,
|
||
_load_inverter_config,
|
||
)
|
||
from services.control.setpoints import (
|
||
_DictRecord,
|
||
_apply_price_failsafe_guard,
|
||
_build_setpoints,
|
||
_clamp_deye_tou_soc_pct,
|
||
_deye_passive_tou_battery_soc_pct,
|
||
_deye_reg143_export_w,
|
||
_deye_system_time_register_rows,
|
||
_deye_time_point_rows,
|
||
_deye_tou_min_soc_pct,
|
||
_deye_tou_params,
|
||
_deye_tou_reserve_soc_pct,
|
||
_deye_zero_export_amps_for_passive,
|
||
get_deye_mode,
|
||
)
|
||
from services.control.verify import (
|
||
_deye_expected_clock_triplet_for_verify,
|
||
_modbus_cmd_register,
|
||
_switch_to_self_sustain,
|
||
_verify_deye_clock_written_bundle,
|
||
verify_modbus_commands,
|
||
)
|
||
from services.modbus_client import get_modbus_client
|
||
from services.signal_service import enqueue_site_signals
|
||
|
||
logger = logging.getLogger(__name__)
|
||
|
||
|
||
async def write_inverter_setpoints(
|
||
site_id: int,
|
||
setpoints_now: ControlSetpoints,
|
||
setpoints_next: ControlSetpoints | None,
|
||
db: asyncpg.Connection,
|
||
planning_run_id: int | None = None,
|
||
) -> str:
|
||
inv = await _load_inverter_config(site_id, db)
|
||
if inv is None:
|
||
return "FAIL inverter: no controllable Modbus endpoint"
|
||
|
||
unit_id = int(inv.unit_id if inv.unit_id is not None else 1)
|
||
raw_bat = setpoints_now.battery_w
|
||
grid_w = int(setpoints_now.grid_setpoint_w or 0)
|
||
no_export = inv.no_export
|
||
export_lim = _deye_reg143_export_w(no_export, inv.max_export_power_w)
|
||
max_batt_w_discharge = int(inv.max_discharge_a * BATT_VOLTAGE_V)
|
||
tp_discharge_w = 0 if setpoints_now.lock_battery else max_batt_w_discharge
|
||
tou_min_pct = _deye_tou_min_soc_pct(inv)
|
||
tou_reserve_pct = _deye_tou_reserve_soc_pct(inv)
|
||
|
||
try:
|
||
soc_telemetry = await _get_current_soc(site_id, db)
|
||
|
||
deye_mode = get_deye_mode(setpoints_now)
|
||
|
||
bat_w = int(raw_bat) if raw_bat is not None else 0
|
||
if setpoints_now.lock_battery:
|
||
charge_a = 0
|
||
discharge_a = 0
|
||
elif deye_mode == "CHARGE":
|
||
charge_a = battery_watts_to_amps(bat_w, inv.max_charge_a)
|
||
discharge_a = 0
|
||
elif deye_mode == "SELL":
|
||
# Záměrný výdej baterie do sítě: plný vybíjecí proud; export strop dle plánu níže.
|
||
charge_a = 0
|
||
discharge_a = int(inv.max_discharge_a)
|
||
elif setpoints_now.self_sustain_local_use:
|
||
# SELF_SUSTAIN: plný nabíjecí i vybíjecí proud invertoru — přebytek FVE jde do baterie,
|
||
# reg. 142 = zero export to load/CT (viz selling_mode níže), ne reg. 108 = 0.
|
||
charge_a = int(inv.max_charge_a)
|
||
discharge_a = int(inv.max_discharge_a)
|
||
else:
|
||
# PASSIVE (ZERO): výchozí plné 108/109; u přetoku FVE do sítě nebo importu bez baterie viz helper.
|
||
charge_a, discharge_a = _deye_zero_export_amps_for_passive(
|
||
grid_w,
|
||
bat_w,
|
||
int(inv.max_charge_a),
|
||
int(inv.max_discharge_a),
|
||
)
|
||
|
||
zero_exp_mode = int(inv.deye_zero_export_mode or 1)
|
||
selling_mode = 0 if deye_mode == "SELL" else zero_exp_mode
|
||
solar_sell = 0 if (setpoints_now.export_ban and deye_mode != "SELL") else 1
|
||
export_limit = export_lim
|
||
if deye_mode == "SELL" and grid_w < 0:
|
||
export_limit = min(export_lim, max(REG143_SELL_CAP_MIN_W, abs(grid_w)))
|
||
reg178_val = REG178_SELL if deye_mode == "SELL" else REG178_PASSIVE
|
||
|
||
logger.info(
|
||
f"[control] site={site_id} fyzický režim Deye: {deye_mode} | "
|
||
f"battery_w={raw_bat!r} grid_w={grid_w} | "
|
||
f"charge_a={charge_a} discharge_a={discharge_a} | "
|
||
f"reg142={selling_mode} reg145={solar_sell} reg143={export_limit}W reg178={reg178_val}"
|
||
)
|
||
|
||
now_cet, time_rows = _deye_system_time_register_rows()
|
||
skip_time = False
|
||
try:
|
||
mb_clock = await get_modbus_client(inv.host, inv.port)
|
||
tvals = await mb_clock.read_holding_registers(
|
||
62, 3, int(inv.unit_id if inv.unit_id is not None else 1)
|
||
)
|
||
if len(tvals) == 3:
|
||
skip_time = _deye_should_skip_time_sync_after_read(
|
||
inv, int(tvals[0]), int(tvals[1]), int(tvals[2])
|
||
)
|
||
else:
|
||
logger.warning(
|
||
"Deye clock read: expected 3 registers, got %s; will sync 62–64",
|
||
len(tvals),
|
||
)
|
||
except Exception as e:
|
||
logger.warning("Deye clock read failed (will sync 62–64): %s", e)
|
||
|
||
if skip_time:
|
||
logger.info(
|
||
"Deye clock 62–64 skipped (drift ≤ %ss, last sync < %sh ago): %s CET",
|
||
DEYE_CLOCK_DRIFT_OK_SEC,
|
||
DEYE_CLOCK_RESYNC_INTERVAL_HOURS,
|
||
now_cet.strftime("%Y-%m-%d %H:%M:%S"),
|
||
)
|
||
else:
|
||
logger.info("Deye time will sync: %s CET", now_cet.strftime("%Y-%m-%d %H:%M:%S"))
|
||
|
||
registers: list[tuple[int, str, int]] = [] if skip_time else list(time_rows)
|
||
|
||
sp_tp2 = setpoints_next if setpoints_next is not None else setpoints_now
|
||
hh_cur = current_slot_hhmm()
|
||
hh_nxt = next_slot_hhmm()
|
||
p1, s1, g1 = _deye_tou_params(setpoints_now, inv)
|
||
p2, s2, g2 = _deye_tou_params(sp_tp2, inv)
|
||
registers.extend(_deye_time_point_rows(0, hh_cur, p1, s1, g1))
|
||
registers.extend(_deye_time_point_rows(1, hh_nxt, p2, s2, g2))
|
||
|
||
prague_date = datetime.now(PRAGUE_TZ).date()
|
||
inactive_sig = (
|
||
f"{DEYE_TOU_INACTIVE_HHMM}|{tou_min_pct}|{tou_reserve_pct}|{tp_discharge_w}"
|
||
)
|
||
need_inactive_tou = (
|
||
inv.deye_last_tou_inactive_write_prague_date != prague_date
|
||
or inv.deye_tou_inactive_signature != inactive_sig
|
||
)
|
||
if need_inactive_tou:
|
||
for idx in range(2, 6):
|
||
registers.extend(
|
||
_deye_time_point_rows(
|
||
idx, DEYE_TOU_INACTIVE_HHMM, tp_discharge_w, tou_min_pct, False
|
||
)
|
||
)
|
||
else:
|
||
logger.debug(
|
||
"Deye TOU rows 3–6 skipped (already written today, signature unchanged)"
|
||
)
|
||
|
||
registers.extend(
|
||
[
|
||
(108, "", charge_a),
|
||
(109, "", discharge_a),
|
||
(141, "energy_mode (0)", 0),
|
||
(142, "limit_control", selling_mode),
|
||
(143, "", export_limit),
|
||
(145, "solar_sell", solar_sell),
|
||
]
|
||
)
|
||
|
||
if (
|
||
bool(inv.deye_reg340_pv_a_control_enabled)
|
||
and int(inv.pv_a_cap_w) > 0
|
||
and setpoints_now.pv_a_allowed_w is not None
|
||
):
|
||
registers.append((340, "max_solar_power_w", int(setpoints_now.pv_a_allowed_w)))
|
||
|
||
# Reg 178: bitové pole. Nastavujeme bits4–5 (peak shaving) vždy; bits0–1 (MI export cutoff) jen pokud feature.
|
||
# Ostatní bity musí zůstat zachované → read-modify-write.
|
||
try:
|
||
mb178 = await get_modbus_client(inv.host, inv.port)
|
||
r178 = await mb178.read_holding_registers(178, 1, unit_id)
|
||
if not r178 or len(r178) < 1:
|
||
raise OSError(f"reg178 read returned {len(r178) if r178 is not None else None} values")
|
||
current_178 = int(r178[0])
|
||
peak_bits = int(reg178_val) & int(REG178_VERIFY_MASK)
|
||
if inv.deye_gen_microinverter_cutoff_enabled:
|
||
want_cutoff = bool(setpoints_now.deye_gen_cutoff_enabled) and deye_mode != "SELL"
|
||
mi_bits = (
|
||
REG178_MI_EXPORT_ENABLE if want_cutoff else REG178_MI_EXPORT_DISABLE
|
||
)
|
||
else:
|
||
mi_bits = int(current_178) & int(REG178_MI_EXPORT_MASK)
|
||
|
||
new_178 = (
|
||
(int(current_178) & ~int(REG178_VERIFY_MASK_COMBINED))
|
||
| int(peak_bits)
|
||
| int(mi_bits)
|
||
)
|
||
registers.append((178, "control_board_special_1", int(new_178)))
|
||
logger.info(
|
||
"[control] %s: reg178 (control_board_special_1) old=%s new=%s peak_bits=0x%04X mi_bits=%s",
|
||
inv.code,
|
||
current_178,
|
||
new_178,
|
||
int(peak_bits),
|
||
int(mi_bits),
|
||
)
|
||
except Exception as e:
|
||
logger.warning("[control] %s: reg178 RMW failed (skip reg178 write): %s", inv.code, e)
|
||
|
||
logger.info(
|
||
"[control] %s: deye_mode=%s charge=%sA discharge=%sA "
|
||
"reg142=%s reg145=%s export=%sW "
|
||
"tp1=%s tp2=%s soc=%s%% (batt=%r grid=%sW)",
|
||
inv.code,
|
||
deye_mode,
|
||
charge_a,
|
||
discharge_a,
|
||
selling_mode,
|
||
solar_sell,
|
||
export_limit,
|
||
hh_cur,
|
||
hh_nxt,
|
||
soc_telemetry,
|
||
raw_bat,
|
||
grid_w,
|
||
)
|
||
|
||
last_verified = await _fetch_last_verified_inverter_registers(site_id, inv.id, db)
|
||
registers, skipped_unchanged = _drop_registers_matching_last_verified(
|
||
registers, last_verified
|
||
)
|
||
if skipped_unchanged:
|
||
logger.info(
|
||
"[control] %s: skip %s registers (value equals last verified): %s",
|
||
inv.code,
|
||
len(skipped_unchanged),
|
||
skipped_unchanged[:24],
|
||
)
|
||
if not registers:
|
||
logger.info(
|
||
"[control] %s: all Deye holding regs match last verified, no Modbus write",
|
||
inv.code,
|
||
)
|
||
if need_inactive_tou:
|
||
await db.execute(
|
||
"""
|
||
UPDATE ems.asset_inverter
|
||
SET deye_last_tou_inactive_write_prague_date = $1,
|
||
deye_tou_inactive_signature = $2
|
||
WHERE id = $3
|
||
""",
|
||
prague_date,
|
||
inactive_sig,
|
||
inv.id,
|
||
)
|
||
return (
|
||
f"OK inverter: batt_w={raw_bat!r} (no changes vs last verified Modbus snapshot)"
|
||
)
|
||
|
||
will_write_inactive = any(
|
||
int(r) in _DEYE_INACTIVE_TOU_REGISTERS for r, _, _ in registers
|
||
)
|
||
|
||
cmd_ids = await create_modbus_commands(
|
||
site_id,
|
||
planning_run_id,
|
||
"inverter",
|
||
inv.id,
|
||
inv.code,
|
||
inv.host,
|
||
inv.port,
|
||
inv.unit_id,
|
||
registers,
|
||
db,
|
||
deye_physical_mode=deye_mode,
|
||
)
|
||
if not await execute_modbus_commands(cmd_ids, db):
|
||
return f"FAIL inverter: {inv.code}: Modbus write failed (see modbus_command)"
|
||
logger.info("[control] Inverter %s journal write OK", inv.code)
|
||
|
||
will_write_time = any(int(r) in DEYE_CLOCK_REGS for r, _, _ in registers)
|
||
if will_write_time:
|
||
await db.execute(
|
||
"""
|
||
UPDATE ems.asset_inverter
|
||
SET deye_last_system_time_sync_minute = $1,
|
||
deye_last_system_time_sync_at = now()
|
||
WHERE id = $2
|
||
""",
|
||
_prague_minute_start_utc(),
|
||
inv.id,
|
||
)
|
||
|
||
if need_inactive_tou or will_write_inactive:
|
||
await db.execute(
|
||
"""
|
||
UPDATE ems.asset_inverter
|
||
SET deye_last_tou_inactive_write_prague_date = $1,
|
||
deye_tou_inactive_signature = $2
|
||
WHERE id = $3
|
||
""",
|
||
prague_date,
|
||
inactive_sig,
|
||
inv.id,
|
||
)
|
||
except Exception as e:
|
||
return f"FAIL inverter: {inv.code}: {e}"
|
||
|
||
return (
|
||
f"OK inverter: batt_w={raw_bat!r} "
|
||
f"(time points + FC 0x10: 108/109/141/142/178/143/145/340 dle plánu)"
|
||
)
|
||
|
||
|
||
async def read_deye_registers_live(site_id: int, db: asyncpg.Connection) -> dict[str, Any]:
|
||
"""
|
||
Živé čtení holding registrů Deye 108, 109, 141–145, 178, 191 a volitelně 340
|
||
(jen pokud `deye_reg340_pv_a_control_enabled`, jinak `reg340_max_solar_power_w` = null).
|
||
Vše pod jedním mutexem + sdružené FC3 bloky — mezi jednotlivými read_register dřív telemetrie
|
||
střídavě brala lock a RS485 brány házely cizí transaction_id / I/O timeouty.
|
||
"""
|
||
inv = await _load_inverter_config(site_id, db)
|
||
if inv is None:
|
||
raise ValueError("no controllable Modbus inverter for site")
|
||
|
||
uid = int(inv.unit_id)
|
||
client = await get_modbus_client(inv.host, inv.port)
|
||
read_at = datetime.now(timezone.utc)
|
||
try:
|
||
async with client.batch(uid) as mb:
|
||
b108 = await mb.read_holding_registers(108, 2)
|
||
b141 = await mb.read_holding_registers(141, 5)
|
||
r178 = await mb.read_holding_registers(178, 1)
|
||
r191 = await mb.read_holding_registers(191, 1)
|
||
if inv.deye_reg340_pv_a_control_enabled:
|
||
r340 = await mb.read_holding_registers(340, 1)
|
||
else:
|
||
r340 = None
|
||
r108, r109 = b108[0], b108[1]
|
||
r141, r142, r143 = b141[0], b141[1], b141[2]
|
||
r145 = b141[4]
|
||
r178 = r178[0]
|
||
r191 = r191[0]
|
||
r340v = (
|
||
int(r340[0])
|
||
if r340 is not None and len(r340) >= 1
|
||
else None
|
||
)
|
||
except Exception:
|
||
logger.exception("read_deye_registers_live site=%s failed", site_id)
|
||
raise
|
||
|
||
return {
|
||
"reg108_charge_a": int(r108),
|
||
"reg109_discharge_a": int(r109),
|
||
"reg141_energy_mode": int(r141),
|
||
"reg142_limit_control": int(r142),
|
||
"reg143_export_limit_w": int(r143),
|
||
"reg145_solar_sell": int(r145),
|
||
"reg178_peak_shaving_switch": int(r178),
|
||
"reg178_control_board_special_1": int(r178),
|
||
"reg178_mi_export_cutoff_bits": int(r178) & int(REG178_MI_EXPORT_MASK),
|
||
"reg178_mi_export_cutoff_is_on": (int(r178) & int(REG178_MI_EXPORT_MASK)) == int(REG178_MI_EXPORT_ENABLE),
|
||
"reg191_peak_shaving_w": int(r191),
|
||
"reg340_max_solar_power_w": r340v,
|
||
"read_at": read_at.isoformat(),
|
||
}
|
||
|
||
|
||
async def export_setpoints(site_id: int, db: asyncpg.Connection) -> None:
|
||
mode = await _fetch_operating_mode(site_id, db)
|
||
if mode is None:
|
||
logger.warning("control export site=%s: no operating mode row", site_id)
|
||
return
|
||
|
||
if mode.mode_code == "MANUAL":
|
||
logger.info("control export site=%s: MANUAL, skip writes", site_id)
|
||
return
|
||
|
||
try:
|
||
inv_for_pv = await _load_inverter_config(site_id, db)
|
||
cap_pv = int(inv_for_pv.pv_a_cap_w) if inv_for_pv is not None else 0
|
||
reg340_en = (
|
||
bool(inv_for_pv.deye_reg340_pv_a_control_enabled)
|
||
if inv_for_pv is not None
|
||
else False
|
||
)
|
||
pi_now = await _fetch_plan_row_for_slot_offset(site_id, db, 0)
|
||
pi_next = await _fetch_plan_row_for_slot_offset(site_id, db, 1)
|
||
sp_now = _build_setpoints(
|
||
mode,
|
||
pi_now,
|
||
pv_a_cap_w=cap_pv,
|
||
reg340_pv_a_control_enabled=reg340_en,
|
||
)
|
||
sp_next = _build_setpoints(
|
||
mode,
|
||
pi_next,
|
||
pv_a_cap_w=cap_pv,
|
||
reg340_pv_a_control_enabled=reg340_en,
|
||
)
|
||
|
||
if mode.mode_code == "AUTO" and sp_now is None:
|
||
if pi_now is None:
|
||
logger.warning(
|
||
"control export site=%s: AUTO but no planning_interval for current slot, skip",
|
||
site_id,
|
||
)
|
||
return
|
||
|
||
if sp_now is None:
|
||
logger.warning(
|
||
"control export site=%s: no setpoints for mode %s, skip",
|
||
site_id,
|
||
mode.mode_code,
|
||
)
|
||
return
|
||
|
||
if mode.mode_code == "CHARGE_CHEAP":
|
||
max_ch = await _fetch_max_charge_power_w(site_id, db)
|
||
# Oba setpointy kladné → get_deye_mode CHARGE; min. 1 W, aby režim nebyl PASSIVE při nulové DB.
|
||
pw = max(1, int(max_ch))
|
||
sp_now = ControlSetpoints(
|
||
battery_w=pw,
|
||
grid_export_limit=0,
|
||
ev1_current_a=0,
|
||
ev2_current_a=0,
|
||
heat_pump_enable=False,
|
||
grid_setpoint_w=pw,
|
||
ev1_power_w=0,
|
||
ev2_power_w=0,
|
||
target_soc_pct=None,
|
||
effective_sell_price_czk_kwh=None,
|
||
)
|
||
sp_next = sp_now
|
||
else:
|
||
sp_now = _apply_price_failsafe_guard(site_id, mode, pi_now, sp_now)
|
||
if sp_next is not None:
|
||
sp_next = _apply_price_failsafe_guard(site_id, mode, pi_next, sp_next)
|
||
|
||
planning_run_id = await db.fetchval(
|
||
"""
|
||
SELECT id FROM ems.planning_run
|
||
WHERE site_id = $1 AND status = 'active'
|
||
ORDER BY created_at DESC
|
||
LIMIT 1
|
||
""",
|
||
site_id,
|
||
)
|
||
if planning_run_id is not None:
|
||
planning_run_id = int(planning_run_id)
|
||
|
||
try:
|
||
inv_res = await write_inverter_setpoints(
|
||
site_id, sp_now, sp_next, db, planning_run_id=planning_run_id
|
||
)
|
||
except Exception as e:
|
||
logger.error("inverter write failed: %s", e)
|
||
inv_res = f"FAIL inverter: {e}"
|
||
|
||
try:
|
||
ev_res = await write_ev_setpoints(site_id, sp_now, db)
|
||
except Exception as e:
|
||
logger.error("ev write failed: %s", e)
|
||
ev_res = f"FAIL ev: {e}"
|
||
|
||
try:
|
||
hp_res = await write_heat_pump_setpoint(site_id, sp_now, db)
|
||
except Exception as e:
|
||
logger.error("hp write failed: %s", e)
|
||
hp_res = f"FAIL heat pump: {e}"
|
||
|
||
try:
|
||
lox_res = await send_loxone_setpoints(site_id, sp_now, mode, db)
|
||
except Exception as e:
|
||
logger.error("loxone write failed: %s", e)
|
||
lox_res = f"FAIL Loxone: {e}"
|
||
|
||
results = list(
|
||
zip(
|
||
("inverter", "ev", "heat_pump", "loxone"),
|
||
(inv_res, ev_res, hp_res, lox_res),
|
||
)
|
||
)
|
||
|
||
for name, res in results:
|
||
if isinstance(res, Exception):
|
||
logger.error("control export site=%s %s: FAIL %s", site_id, name, res)
|
||
elif isinstance(res, str) and res.startswith("FAIL"):
|
||
logger.error("control export site=%s %s: %s", site_id, name, res)
|
||
else:
|
||
logger.info("control export site=%s %s: %s", site_id, name, res)
|
||
finally:
|
||
try:
|
||
await enqueue_site_signals(site_id, db)
|
||
except Exception as e:
|
||
logger.warning(
|
||
"control export site=%s: signal enqueue failed: %s", site_id, e
|
||
)
|