"""Datové modely pro control export."""
from __future__ import annotations
from dataclasses import dataclass
from datetime import date, datetime
@dataclass
class InverterConfig:
id: int
code: str
host: str
port: int
unit_id: int
max_export_power_w: int | None
max_import_power_w: int | None
no_export: bool
max_battery_charge_w: int | None
max_battery_discharge_w: int | None
min_soc_percent: int | None
reserve_soc_percent: int | None
max_soc_percent: int | None
usable_capacity_wh: int | None
max_charge_a: int
max_discharge_a: int
deye_last_system_time_sync_minute: datetime | None = None
deye_last_system_time_sync_at: datetime | None = None
deye_last_tou_inactive_write_prague_date: date | None = None
deye_tou_inactive_signature: str | None = None
deye_zero_export_mode: int = 1
deye_gen_microinverter_cutoff_enabled: bool = False
#: Strop reg 340 (W) z fn_inverter_pv_a_max_w; 0 = EMS nezapisuje reg 340.
pv_a_cap_w: int = 0
#: Minimální hodnota reg 340 přijatá firmwarem (0 nebo např. 400 u staršího Deye).
pv_a_reg340_min_w: int = 0
#: True = EMS smí řídit Deye reg 340 (max solar power); z SQL `fn_site_has_active_green_bonus_pv(site_id)`.
deye_reg340_pv_a_control_enabled: bool = False
@dataclass
class ControlSetpoints:
battery_w: int | None
#: Tvrdý limit exportu do sítě v daném slotu (W), ne forecastová cílová hodnota.
grid_export_limit: int
ev1_current_a: int
ev2_current_a: int
heat_pump_enable: bool
grid_setpoint_w: int
ev1_power_w: int
ev2_power_w: int
target_soc_pct: int | None = None
#: Explicitní fyzický režim z plánu (PASSIVE/SELL/CHARGE).
deye_physical_mode: str | None = None
#: Záměr exportu z LP: NONE / PV_SURPLUS / BATTERY_SELL.
export_mode: str | None = None
#: True = zákaz exportu (BLOCK_EXPORT) pro daný slot.
export_ban: bool = False
#: True = odpojit GEN port (MI export cutoff) v tomto slotu dle plánu (reg 178 bits0-1).
deye_gen_cutoff_enabled: bool = False
#: Efektivní vykupní cena slotu (Kč/kWh z plánu).
effective_sell_price_czk_kwh: float | None = None
#: True = reg 108/109 na 0 (PRESERVE - Deye baterii nepoužívá).
lock_battery: bool = False
#: Režim SELF_SUSTAIN.
self_sustain_local_use: bool = False
#: Deye reg 340 (max solar power, W). None = EMS reg 340 v tomto ticku neřeší.
pv_a_allowed_w: int | None = None
@dataclass
class OperatingModeInfo:
mode_code: str
battery_mode: str
grid_mode: str
ev_enabled: bool
heat_pump_enabled_def: bool
loxone_mode_value: int